• English
    • Persian
  • Persian 
    • English
    • Persian
  • ورود
مشاهده آیتم 
  •   صفحه اصلی مخزن دانش
  • School of Medicine
  • Theses(M)
  • مشاهده آیتم
  •   صفحه اصلی مخزن دانش
  • School of Medicine
  • Theses(M)
  • مشاهده آیتم
JavaScript is disabled for your browser. Some features of this site may not work without it.

Deep Learning-Based Attenuation Correction for 68Ga-Dotatate Whole-Body PET Imaging

Thumbnail
تاریخ
2024
نویسنده
Sobhi Lord, Mahsa
Metadata
نمایش پرونده کامل آیتم
چکیده
Attenuation correction is a critical phenomenon in quantitative PET imaging with its own special challenges. However, computerized tomography (CT) modality which is used for attenuation correction and anatomical localization increases patient radiation dose. This study was aimed to develop a deep learning model for attenuation correction of whole-body 68Ga-DOTATATE PET images. Methods: Non-attenuation corrected (NAC) and CT-based attenuation corrected (CTAC) whole-body 68Ga-DOTATATE PET images of 118 patients from two different imaging centers were used. We implemented a residual deep learning model using the NiftyNet framework. The model was trained four times and evaluated six times using the test data from the centers. Quality of the synthesized PET images were compared with the PET-CTAC images using different evaluation metrics, including peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), mean square error (MSE), and root mean square error (RMSE). Results: Quantitative analysis of four network training sessions and six evaluations revealed the highest and lowest PSNR values as (52.86 ± 6.6) and (47.96 ± 5.09), respectively. Similarly, the highest and lowest SSIM values were obtained (0.99 ± 0.003) and (0.97 ± 0.01), respectively. Additionally, the highest and lowest RMSE and MSE values fell within the ranges of (0.0117 ± 0.003), (0.0015 ± 0.000103), and (0.01072 ± 0.002), (0.000121 ± 5.07×e^(-5)), respectively. The results indicated that the highest PSNR was associated with the training and testing datasets originating from the same center. Conversely, the evaluations that involved training and testing datasets from different centers exhibited the lowest PSNR and SSIM values, while demonstrating the highest MSE and RMSE values. Furthermore, the evaluations with the highest SSIM and the lowest MSE and RMSE were associated with scenarios in which datasets from both centers were used for network training and testing.
URI
https://dspace.tbzmed.ac.ir:443/xmlui/handle/123456789/71728
Collections
  • Theses(M)

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV