Show simple item record

dc.contributor.authorHashemzadeh, Nastaran
dc.date.accessioned2022-01-30T10:47:03Z
dc.date.available2022-01-30T10:47:03Z
dc.date.issued2015en_US
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/66061
dc.description.abstractIntroduction: Nowadays anticancer drugs which used as chemotherapy regimen for patients are become more useful. The development of an accurate and repeatable method for determination of these drugs, will improve our understanding of their role in the treatment process. One of the common methods of determining the trace amount of these drugs is electrochemical methods. According to the importance of these methods in the analysis of drugs, in the present study graphene quantum dots (GQDs) used as active ingredient in the preparation of electrochemical sensors. Application of prepared electrochemical sensor for the detection and quantification of doxorubicin in biological samples were studied. Aim: Developing an electrochemical sensor based on graphene quantum dots and its application for the detection and determination of doxorubicin (DOX) in biological samples. Methods: In this study, GQDs were synthesized by pyrolyzing citric acid in alkaline solution.The UV–Vis spectroscopy, X-ray diffraction (XRD), transition electron microscopy (TEM), Fourier transform infrared (Ft-IR) spectroscopy, Atomic force microscopy (AFM) and cyclic and differential pulse voltammetric techniques were used for characterizing synthesized GQDs. The electrochemical behavior of GQD modified glassy carbon electrode (GQD-GCE) was studied using cyclic voltammetry (CV) technique. The electrochemical behavior of DOX was investigated at the GQD-GCE in phosphate buffer solution (PBS), using differential pulse voltammetry technique (DPV). Results and Conclusion: electrochemical behavior GQD-GCE was studied using CV and DPV. DPV was used to evaluate the analytical performance of DOX in the presence of PBS (pH 4) and good limit of detection was obtained by proposed sensor. The results revealed that GQD promotes the rate of oxidation by increasing the peak current. Finally, the applicability of the proposed method was described to the direct assays of spiked human plasma.en_US
dc.language.isoenen_US
dc.publisherTabriz University of Medical Science, School of pharmacyen_US
dc.subjectDoxorubicinen_US
dc.subjectElectrochemical sensoren_US
dc.subjectGraphene Quantum Doten_US
dc.subjectGlassy carbon electrodeen_US
dc.subjectHuman plasmaen_US
dc.titleApplication of Graphene Quantom dot on determination of ِDoxorubicin on biological samplesen_US
dc.typeThesisen_US
dc.contributor.supervisorJouyban, Abolghasem
dc.contributor.supervisorShadjou, Nasrin
dc.identifier.callno3760en_US
dc.description.disciplinePharmacyen_US
dc.description.degreePharm Den_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record