نمایش پرونده ساده آیتم

dc.contributor.authorSadigh, AL
dc.contributor.authorAali, TA
dc.contributor.authorSadeghi, A
dc.date.accessioned2018-08-26T09:31:36Z
dc.date.available2018-08-26T09:31:36Z
dc.date.issued2015
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/57111
dc.description.abstractPurpose: To report the results of intrastromal corneal ring segment (KeraRing; Mediphcose, Belo Horizonte, Brazil) implantation relative to depth of insertion in keratoconic patients. Methods: In this retrospective, observational study, we evaluated 29 eyes of 27 patients with keratoconus who underwent implantation of KeraRing SI-5 with mechanical tunnel creation. In the mean follow-up of 8.8 months, all eyes underwent scheimpfluge image of pentacam (Oculus, Germany) to determine insertion depth. Based on the measured implantation depth, cases were categorized into: 40-59% thickness group, 60-79% thickness group, and ?80% thickness group. Visual, refractive, and shape outcomes were evaluated relative to implantation depth. Results: The mean insertion depth was 61.7%.We had 41.4% of cases were in the 40-59% thickness group, 51.7% in the 60-79% group, and 6.9% in the >80% group. Results were similar in 40-59% and 60-79% thickness groups: uncorrected visual acuity (UCVA) and best spectacle corrected VA (BSCVA) improved 3 and 2 lines, respectively, maximum keratometry (Kmax) decreased 2.6 D, refractive cylinder improved 2.04 D, and Q value 8 mm anterior changed by 0.35. In the ?80% thickness group, UCVA and BSCVA improved less than 1 lines, Kmax change was less than 0.5 D, and RC decreased less than 0.25 D. Conclusion: Implantation of KeraRing with mechanical tunnel creation in 40-80% of stromal thickness despite the variable insertion depth is effective. © 2015 Iranian Society of Ophthalmology.
dc.language.isoEnglish
dc.relation.ispartofJournal of Current Ophthalmology
dc.subjectadolescent
dc.subjectadult
dc.subjectArticle
dc.subjectbest spectacle corrected visual acuity
dc.subjectclinical article
dc.subjectcontrolled study
dc.subjectcornea thickness
dc.subjectfemale
dc.subjectfollow up
dc.subjecthuman
dc.subjectintrastromal corneal ring segment
dc.subjectkeratoconus
dc.subjectkeratometry
dc.subjectmale
dc.subjectobservational study
dc.subjectophthalmic camera
dc.subjectretrospective study
dc.subjectscheimpflug image
dc.subjectuncorrected visual acuity
dc.subjectvisual acuity
dc.subjectvisual system parameters
dc.titleOutcome of intrastromal corneal ring segment relative to depth of insertion evaluated with scheimpflug image
dc.typeArticle
dc.citation.volume27
dc.citation.issue1-2
dc.citation.spage25
dc.citation.epage31
dc.citation.indexScopus
dc.identifier.DOIhttps://doi.org/10.1016/j.joco.2015.09.009