Outcome of intrastromal corneal ring segment relative to depth of insertion evaluated with scheimpflug image

Thumbnail
نمایش/بازکردن
main.pdf (6.019Mb)
تاریخ
2015
نویسنده
Sadigh, AL
Aali, TA
Sadeghi, A
Metadata
نمایش پرونده کامل آیتم
چکیده
Purpose: To report the results of intrastromal corneal ring segment (KeraRing; Mediphcose, Belo Horizonte, Brazil) implantation relative to depth of insertion in keratoconic patients. Methods: In this retrospective, observational study, we evaluated 29 eyes of 27 patients with keratoconus who underwent implantation of KeraRing SI-5 with mechanical tunnel creation. In the mean follow-up of 8.8 months, all eyes underwent scheimpfluge image of pentacam (Oculus, Germany) to determine insertion depth. Based on the measured implantation depth, cases were categorized into: 40-59% thickness group, 60-79% thickness group, and ?80% thickness group. Visual, refractive, and shape outcomes were evaluated relative to implantation depth. Results: The mean insertion depth was 61.7%.We had 41.4% of cases were in the 40-59% thickness group, 51.7% in the 60-79% group, and 6.9% in the >80% group. Results were similar in 40-59% and 60-79% thickness groups: uncorrected visual acuity (UCVA) and best spectacle corrected VA (BSCVA) improved 3 and 2 lines, respectively, maximum keratometry (Kmax) decreased 2.6 D, refractive cylinder improved 2.04 D, and Q value 8 mm anterior changed by 0.35. In the ?80% thickness group, UCVA and BSCVA improved less than 1 lines, Kmax change was less than 0.5 D, and RC decreased less than 0.25 D. Conclusion: Implantation of KeraRing with mechanical tunnel creation in 40-80% of stromal thickness despite the variable insertion depth is effective. © 2015 Iranian Society of Ophthalmology.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/57111
Collections
  • Published Articles

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV