Determination of synthetic phenolic antioxidants in biological fluids based on airassisted liquid-liquid microextraction followed by gas chromatography-flame ionization detection

Thumbnail
نمایش/بازکردن
ABCR_Volume 3_Issue 2_Pages 239-251.pdf (320.5Kb)
تاریخ
2016
نویسنده
Farajzadeh, MA
Abbaspour, M
Afshar Mogaddam, MR
Alizadeh Nabil, AA
Metadata
نمایش پرونده کامل آیتم
چکیده
An air-assisted liquid-liquid microextraction method for the extraction and preconcentration of trace amounts of some synthetic phenolic antioxidants in biological fluids followed by their determination by gas chromatography-flame ionization detection has been reported. In this method the target analytes are extracted into a few microliters of carbon tetrachloride (extraction solvent) from an aqueous solution by aspirating and dispersing the extraction solvent and sample solution mixture by a syringe. After extraction, phase separation is performed by centrifugation and the enriched analytes in the sedimented phase are determined. The parameters affecting the extraction efficiency including the type and volume of extraction solvent, salt addition, extraction times, and pH are investigated in details. Under the optimum extraction conditions, the method shows low limits of detection and quantification between 0.8-1.8 and 2.7-5.6 ng ml-1, respectively. The method is applied to determine some phenolic antioxidants in biological samples and extraction recoveries are ranged from 63-81%. Enrichment factors are obtained between 315 and 405. The method shows good linearities in the range of 3-6000 ng ml-1 with the correlation coefficients higher than 0.996. Relative standard deviations are lower than 8% for intra-day (n = 6) and inter-day (n = 4) precisions. Finally the proposed method is successfully used for determination of the analytes in urine and plasma samples.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/53457
Collections
  • Published Articles

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV