• English
    • Persian
  • Persian 
    • English
    • Persian
  • ورود
مشاهده آیتم 
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
JavaScript is disabled for your browser. Some features of this site may not work without it.

The Effect of Repetition Time on the Maximum Linear Relationship Between Contrast Agent Concentration and Signal Intensity on T1-Weighted Image Using Inversion Recovery (IR) Sequence

Thumbnail
نمایش/بازکردن
iranjradiol-1774.pdf (249.7Kb)
تاریخ
2009
نویسنده
Nazarpoor, M
Metadata
نمایش پرونده کامل آیتم
چکیده
Background/Objective: The relaxation time T1 depends on the concentration of paramagnetic contrast agent. To calculate perfusion parameters from dynamic contrast-enhanced MRI acquisitions, measurement of the concentration is necessary. At low concentrations, the relationship between changes in 1/T1 and concentration can be considered to be linear. To maximize the concentration, and hence the signal to noise ratio (SNR) in perfusion images, the range of this linearity should be known. This work studied the effect of two repetition times (TR) on the linearity using inversion recovery Turbo Fast Low Angle Shot (TurboFLASH) sequences at different effective inversion times (T1). Patients and Methods: To assess the relationship between signal intensity (SI) and concentration. a water-filled phantom containing vials of different concentrations of Gd-DTPA (0 to 19.77 mmol/L) was used. The mean SI was obtained in the region of interest using T1-weighted images. Coil non-uniformity was corrected on SI. Results: This study shows that an increase in TR is associated with a decrease in the maximum linear relationship between effective T1 and concentration where the square correlation (R-2) between corrected SI and concentration were equal to 0.95 or 0.99. Conclusion: In spite of TR = 2 or 3s and r(2) = 0.95 or 0.99 at a typical effective T1 = 800ms, which is normally used for in vivo perfusion, the maximum linearity is about twice that previously reported (i.e. 0.8mmol/L) for measuring the perfusion parameters. The higher dose, will improve the SNR in perfusion images.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/51129
Collections
  • Published Articles

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV