Inflow Effect Correction in Perfusion Measurement of Normal Subjects with T1-Weighted Images Using Inversion Recovery Sequences

Thumbnail
نمایش/بازکردن
iranjradiol-07-03-1681.pdf (531.5Kb)
تاریخ
2010
نویسنده
Nazarpoor, M
Morgan, PS
Metadata
نمایش پرونده کامل آیتم
چکیده
Background/Objective: A dynamic contrast-enhanced T1 technique has been applied for calculating cerebral blood flow (CBF) with MRI. Previous Studies have shown that the CBF calculated from T1 techniques was lower than the expected CBE One cause could be the change in MRI signal intensity due to blood flowing into the measurement slice. The aims of this paper were: 1. To quantify the effects of inflow on perfusion measurements using a phantom. 2. To apply a simple inflow correction to perfusion measurements taken from 11 healthy subjects. Patients and Methods: A flow phantom was designed to produce different velocities covering the velocity range of small vessels and big arteries. The inflow effects were measured in the phantom. After the contrast administration for healthy subjects. CBF was calculated based on T1 technique. Results: The inflow correction factor for the common carotid artery velocity and capillary level was calculated by the phantom as 1.23 and 1, respectively. The average value of CBF on the middle cerebral artery (MCA) grey matter territory of 11 healthy volunteers without any correction was 43.0 mL/100 g/min. Conclusion: For measuring the absolute CBE the inflow correction factor for the arterial input function and tissue should be known. After applying the inflow correction factors, the absolute CBF may be calculated as 52.9 mL/100 g/min. This value is in good agreement with those in the PET literature.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/50815
Collections
  • Published Articles

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV