• English
    • Persian
  • Persian 
    • English
    • Persian
  • ورود
مشاهده آیتم 
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
JavaScript is disabled for your browser. Some features of this site may not work without it.

Accuracy of Implant Placement Using a CAD/CAM Surgical Guide: An In Vitro Study

Thumbnail
تاریخ
2011
نویسنده
Nokar, S
Moslehifard, E
Bahman, T
Bayanzadeh, M
Nasirpouri, F
Nokar, A
Metadata
نمایش پرونده کامل آیتم
چکیده
Purpose: To determine and compare the accuracy of an advanced surgical template based on computer-aided design/computer-assisted manufacture (CAD/CAM) with the conventional surgical template in different respects such as entry point, length, and osteotomy angle. Materials and Methods: Computed tomography (CT) scanning of a dentate epoxy mandible was performed and its three-dimensional computerized model was simulated. Sixteen rapid-prototyped models were fabricated and divided into two groups. In the first group, a radiographic template was fabricated and placed on the model during CT scanning and then was modified to the conventional surgical template form. In the second group, a coordinate measuring machine was used to reformat a nonanatomic radiographic template fabricated by a stereolithographic machine, and four implants were planned and then placed in the jaw. The differences between planned and actual mesiodistal and buccolingual entry points, lengths, and angles of the implants were measured. Statistical analysis was performed with the Mann-Whitney and Friedman tests to detect differences between groups. Results: The average differences between the planned and actual entry points in the mesiodistal and buccolingual directions, lengths, and angles of the implants and the osteotomy showed a considerable reduction in the CAD/CAM group versus the conventional group (P < .005). Conclusion: The accuracy of implant placement was improved using an innovative CAD/CAM surgical template. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:520-526
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/50310
Collections
  • Published Articles

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV