• English
    • Persian
  • Persian 
    • English
    • Persian
  • ورود
مشاهده آیتم 
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
JavaScript is disabled for your browser. Some features of this site may not work without it.

Comparison of the Spo(2)/Fio(2) Ratio and the Pao(2)/Fio(2) Ratio in Patients With Acute Lung Injury or Acute Respiratory Distress Syndrome

Thumbnail
تاریخ
2015
نویسنده
Bilan, N|| Dastranji, A|| Behbahani, AG
Metadata
نمایش پرونده کامل آیتم
چکیده
Introduction: Diagnostic criteria for acute lung injury (ALI) and Acute Respiratory Distress syndrome (ARDS) includes acute onset of disease, chest radiograph demonstrating bilateral pulmonary infiltrates, lack of significant left ventricular dysfunction and Pao(2)/Fio(2) (PF) ratio <= 300 for ALI or <= 200 for ARDS. Recent criteria require invasive arterial sampling. The pulse oximetric saturation Spo(2)/Fio(2) (SF) ratio may be a reliable non-invasive alternative to the PF ratio. Methods: In this cross-sectional study, we enrolled 70 patients with ALI or ARDS who were admitted in Tabriz children's hospital pediatrics intensive care unit (PICU). Spo(2), Fio(2), Pao(2), charted within 5 minutes of each other and calculated SF and PF were recorded to determine the relationship between SF and PF ratio. SF values were examined as a substitute of PF ratio for diagnosis ARDS and ALI. Results: The relationship between SF and PF ratio was described by the following regression equation: SF=57+0.61 PF (P<0.001). SF ratios of 181 and 235 corresponded of PF ratio 300 and 200. The SF cutoff of 235 had 57% sensitivity and 100% specificity for diagnosis of ALI. The SF cutoff of 181 had 71% sensitivity and 82% specificity for diagnosis of ARDS. Conclusion: SF ratio is a reliable noninvasive surrogate for PF ratio to identify children with ALI or ARDS with the advantage of replacing invasive arterial blood sampling by non-invasive pulse oximetry.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/48256
Collections
  • Published Articles

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV