• English
    • Persian
  • Persian 
    • English
    • Persian
  • ورود
مشاهده آیتم 
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
JavaScript is disabled for your browser. Some features of this site may not work without it.

Correlation between Nonreassuring Patterns in Fetal Cardiotocography and Birth Asphyxia

Thumbnail
تاریخ
2015
نویسنده
Abbasalizadeh, F
Abbasalizadeh, S
Pouraliakbar, S
Bastani, P
Metadata
نمایش پرونده کامل آیتم
چکیده
Objectives: Cardiotocography (CTG) is a tool for assessing the fetus during labor and identifying the risk of asphyxia. Abnormal CTG can lead to stress in the physician and mother and result in their decision in terminating the pregnancy and the complications of an emergency cesarean section. The purpose of this study was the evaluation of the correlation between nonreassuring patterns in fetal CTG and birth asphyxia. Materials and Methods: In a cross-sectional analytic study, 324 term pregnant women were included. The association between nonreassuring patterns in CTG (fetal tachycardia, fetal bradycardia, absent or minimal baseline variability, and absence of acceleration and periodic or episodic deceleration) and birth asphyxia were assessed. Results: Birth asphyxia existed in 10 newborns; in all cases mild hypoxic ischemic encephalopathy (HIE) was observed. Within the nonreassuring CTG patterns, baseline fetal heart variability and periodic or episodic deceleration had a significant relationship with birth asphyxia. Most asphyxia cases had occurred in absent and minimal baseline fetal heart rate (FHR) variability (R = 0.49, P <.001). In periodic or episodic decelerations, most asphyxia cases occurred in recurrent late decelerations with normal baseline variability and variable decelerations with shoulders or overshoots(R=0.42, P =.014). Conclusion: With regard to the findings of the present study we can use nonreassuring cardiotocographic patterns, especially absent and minimal baseline FHR variability and periodic or episodic decelerations in prediction of birth asphyxia. It seems however that most birth asphyxias occur in normal cardiotocographs.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/47884
Collections
  • Published Articles

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV