• English
    • Persian
  • Persian 
    • English
    • Persian
  • ورود
مشاهده آیتم 
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
JavaScript is disabled for your browser. Some features of this site may not work without it.

Comparison of the patient radiation exposure during coronary angiography and angioplasty procedures using trans-radial and transfemoral access

Thumbnail
تاریخ
2016
نویسنده
Tarighatnia, A
Alian, AHM
Ghojazadeh, M
Farajollahi, AR
Metadata
نمایش پرونده کامل آیتم
چکیده
Introduction: Cardiac catheterization procedure through the trans-radial access (TRA) have shown many clinical advantages over the trans-femoral (TFA), but despite its advantages, there are serious concerns regarding higher possible radiation dose for the patients and operators in TRA. This study was planned to compare the patients' radiation dose associated with TRA and TFA during coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA). Methods: Of 700 candidates for angiography, 326 patients were entered the study. All the procedures were carried out by one interventional cardiologist employing the same angiography unit in Aalinasab hospital and the patients' dose area product (DAP), air kerma (AK), fluoroscopy time (FT) and cine film time (CFT) were then determined in both access groups (TRA, TFA) in CA, PTCA and CA+PTCA procedures. Results: The mean FT, CFT and AK values in both TRA & TFA groups were the same in all procedures (P > 0.05). The mean DAP in CA+PTCA procedures was 6704.01 +/- 3243.23 mu Gym(2) in femoral access compare with 5647.46 +/- 2797.74 mu Gym(2) in radial access, which were significantly less than that in TFA with P = 0.02. Conclusion: On the basis of the results obtained in this study, no differences were found in patients' radiation dose in both access groups, therefore with regard to comparatively more clinical advantages associated with the Trans-radial access technique it might be a good substitute for Trans-femoral access.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/47419
Collections
  • Published Articles

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV