• English
    • Persian
  • Persian 
    • English
    • Persian
  • ورود
مشاهده آیتم 
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
JavaScript is disabled for your browser. Some features of this site may not work without it.

Effect of hemodialysis on pulmonary function tests and plasma endothelin levels.

Thumbnail
تاریخ
2014
نویسنده
Safa, J
Noshad, H
Ansarin, K
Nikzad, A
Saleh, P
Ranjbar, A
Metadata
نمایش پرونده کامل آیتم
چکیده
End-stage renal disease (ESRD) is a complex illness that involves different organs including the lungs. We studied the pulmonary function tests, arterial blood gases (ABG) and plasma endothelin-1 (ET-1) levels to check whether there is any change in their levels after hemodialysis (HD) in patients with ESRD. In this cross-sectional study (from July 2009 to April 2010), 20 patients with ESRD were evaluated. ABG, spirometric parameters and plasma ET-1 were measured before and after HD in these patients. Student's t-test was performed to clarify the differences and Pearson's test was used for correlations. P <0.05 was considered statistically significant. Significant reduction was seen in oxygen saturation (O?sat), partial pressure of carbon-dioxide (PaCO?) and oxygen (PaO?) after a HD session (P <0.001). Also, improvement was seen in all spirometric parameters except forced expiratory volume (FEV1)/forced vital capacity (FVC) after HD. Plasma ET-1 levels decreased significantly after HD. Mean ET-1 before HD was 6.88 + 5.81 pg/mL while it was 3.91 + 2.76 pg/mL after HD (P = 0.009). Based on the plasma levels of ET-1, the patients were divided into two groups. The mean level of ET-1 was higher in the first group. Significant increase was seen in spirometric parameters in the second group. Our study suggests that, in patients with ESRD, plasma ET-1 level is higher than in the normal population, and this is closely related to deterioration of pulmonary function tests. Significant reduction of plasma ET-1 may be an important factor in the improvement of spiro-metry parameters after HD.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/41593
Collections
  • Published Articles

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV