• English
    • Persian
    • English
    • Persian
  • Persian 
    • English
    • Persian
    • English
    • Persian
  • ورود
مشاهده آیتم 
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
JavaScript is disabled for your browser. Some features of this site may not work without it.

Comparison of multiple rebond shear strengths of debonded brackets after preparation with sandblasting and CO2 laser.

Thumbnail
تاریخ
2016
نویسنده
Kachoei, M
Mohammadi, A
Esmaili Moghaddam, M
Rikhtegaran, S
Pourghaznein, M
Shirazi, S
Metadata
نمایش پرونده کامل آیتم
چکیده
Background. Failure of orthodontic bracket bonds is a common occurrence during orthodontic treatment. Different techniques have been suggested in the literature to remove resin residues from the bracket bases and enamel surfaces to prepare the surfaces again after debonding. This study attempted to compare multiple rebond shear strengths (SBS) of debonded brackets following preparation with sandblasting and CO2 laser. Methods. The brackets were bonded on 30 human and bovine maxillary central incisors using self-curing composite resin. SBS was measured using Hounsfield testing machine. The brackets were rebonded for two other times after composite resin residues on their surfaces were removed, either with air abrasion or CO2 laser. The debonded brackets and enamel surfaces were also evaluated after each debonding procedure under a stereomicroscope in order to determine adhesive remnant index (ARI). SBS of debonded brackets after each step were compared between sandblast and CO2 laser groups. Results. We observed significant differences in SBS values between pre-recycling and first (P = 0.04), second (P = 0.007) and third recycling (P = 0.007) with laser. Recycling with sandblasting resulted in a decrease in SBS after the first and second recycling procedure; however, the SBS increased after the third recycling procedure, with no significant differences. Conclusion. SBS of brackets after recycling with sandblasting and laser beams was not significantly different, and both were at a favorable level. However, repeating the recycling procedure with sandblasting resulted in more favorable SBS compared to laser.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/39648
Collections
  • Published Articles

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV