• English
    • Persian
  • Persian 
    • English
    • Persian
  • ورود
مشاهده آیتم 
  •   صفحه اصلی مخزن دانش
  • School of Dentistry
  • Theses(D)
  • مشاهده آیتم
  •   صفحه اصلی مخزن دانش
  • School of Dentistry
  • Theses(D)
  • مشاهده آیتم
JavaScript is disabled for your browser. Some features of this site may not work without it.

Evaluation of the influence of crown material and abutment material on the retrievability of cement-retained implant-supported crowns with lingual retrieval slots

Thumbnail
نمایش/بازکردن
sevda mashadi jolfaei thesis.pdf (1.254Mb)
تاریخ
2020
نویسنده
Mashhadi Jolfaei, Sevda
Metadata
نمایش پرونده کامل آیتم
چکیده
Background and goal: The ability to the retrieve implant-supported crowns is important to solve mechanical, biological and aesthetic problems. The aim of this study was to evaluation of the influence of crown material and abutment material on the retrievability of cement-retained implant-supported crowns with lingual retrieval slots. Materials and methods: In this in-vitro study, 24 samples were examined in three groups. Group 1: base metal crowns cemented to titanium abutments (n=8), Group 2: zirconia crowns cemented to titanium abutments (n=8), Group 3: zirconia crowns cemented to zirconia abutments (n=8). All abutments were have rectangular ledges (2mm*1mm) for the retrieval slots and all crowns were have lingual retrieval slots (2mm*1mm), coronally to abutment ledge. All abutments, zirconia crowns and resin copings (for casting base metal crowns) were be fabricated using a CAD/CAM system. The abutments and crowns were be cemented together with RMGI cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device we were record the maximum torque (N.cm) required to remove the crowns. Data were analyzed by SPSS 20 software using t-test. (P value≤0.05) Results: The removal torque in group two (zirconia crowns cemented to titanium abutments) was significantly lower than group one (base metal crowns cemented to titanium abutments). Mean removal torque for each group was 38.75±3.53 (BM-Ti) , 31.75±2.86 (Zr-Ti) and 37.33±11.9 (Zr-Zr). Discussion The influence of crown material and abutment material on the retrievability of cement-retained implant-supported crowns with lingual retrieval slots is significant.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/63013
Collections
  • Theses(D)

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV