• English
    • Persian
  • English 
    • English
    • Persian
  • Login
View Item 
  •   KR-TBZMED Home
  • TBZMED Published Academics Works
  • Published Articles
  • View Item
  •   KR-TBZMED Home
  • TBZMED Published Academics Works
  • Published Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

The effect of photodynamic therapy and polymer solution containing nano-particles of Ag /ZnO on push-out bond strength of the sealers AH-Plus and MTA Fillapex

Thumbnail
Date
2017
Author
Yavari, H
Ghasemi, N
Divband, B
Rezaei, Y
Jabbari, G
Payahoo, S
Metadata
Show full item record
Abstract
Background: The aim of this in vitro study was to examine and compare the effect of photodynamic therapy and solution containing nano particles Ag/ZnO on adhesion of endodontic sealers to dentinal walls of human root canal. Material and Methods: Ninty single-rooted human teeth were selected and their clinical crown was cut from the cemento-enamel junction zone. Canals were prepared by RaCe rotary system and the smear layer was removed using 17% EDTA and 5.25% NaOCl. Samples were randomly divided into two groups of AH Plus and MTA Fillapex based on the sealer type and each group based on antimicrobial method was divided into two sub-groups of photodynamic therapy and polymer containing nano particles of Ag / ZnO and a control sub-group (N = 15). After obturation of canals with gutta-percha and sealers mentioned, the samples were incubated for a week at a humidity of 95% and 37°C and then 2mm thick discs were prepared from the middle region of roots for Push-out test. The maximum failure force was recorded in newton and converted to MPa. Then, 3 random specimens of each subgroup were evaluated by scanning electron microscopy. Statistical analysis was performed by Two way ANOVA and (P < 0.05) was considered significant. Results: The highest (4.84 ± 1.63) and lowest (0.16 ± 0.075) push-out bond strength values were obtained in (AH Plus-PDT) and (MTA Fillapex-Ag/ZnO) respectively. Independent of antimicrobial method, AH Plus bond strength was significantly higher than the MTA Fillapex (p < 0.001). For both sealers, PDT increased the bond strength significantly (p < 0.001). Conclusions: Photodynamic therapy has a positive effect on the bond strength of AH Plus and MTA Fillapex sealers. © Medicina Oral S. L. C.I.F.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/58297
Collections
  • Published Articles

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of KR-TBZMEDCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV