Optical characterization of NIPAM and PAGAT polymer gels for radiation dosimetry
Abstract
Introduction: The purpose of the current study was to determine optical sensitivity of N-isopropyl acrylamide NIPAM and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (PAGAT) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. Materials and Methods: NIPAM and PAGAT polymer gels with conventional formulations used for polymer gel dosimetry in radiation therapy were prepared. Using a laboratory spectrophotometer, light absorbance against wavelength of light spectrum from 400 to 700 nm was measured. The optical absorbance-dose response curves were obtained for different wavelengths and the results were compared to find the wavelength where the highest sensitivity of polymer gels is occurred. Results: The results showed light wavelength dependency for polymer gels optical absorbance-dose sensitivity. The highest sensitivity was seen in the blue part of visible light at wavelengths of 440 and 460 nm for PAGAT and NIPAM, respectively. Moreover, the sensitivity of NIPAM gel was higher than PAGAT for all studied wavelengths. Conclusion: The sensitivity of both gels varied considerably with light wavelength and was higher in shorter wavelength of visible light. It is recommended to study optical absorbance-dose sensitivity of polymer gels for selecting the optimum light wavelength for optical measurements and optical computed tomography applications.
Collections
Related items
Showing items related by title, author, creator and subject.
-
Optical computed tomography in PRESAGE three-dimensional dosimetry: Challenges and prospective
Khezerloo, D; Nedaie, H; Farhood, B; Zirak, A; Takavar, A; Banaee, N; Ahmadalidokht, I; Kron, T (2017)With the advent of new complex but precise radiotherapy techniques, the demands for an accurate, feasible three-dimensional (3D) dosimetry system have been increased. A 3D dosimeter system generally should not only have ... -
3D curvelet-based segmentation & quantification of drusen in optical coherence tomography images
Esmaeili, M; Dehnavi, AM; Rabbani, H (2017)Spectral-Domain Optical Coherence Tomography (SD-OCT) is a widely used interferometric diagnostic technique in ophthalmology that provides novel in vivo information of depth-resolved inner and outer retinal structures. ... -
Achondroplasia and macular coloboma
Ahoor, MH; Amizadeh, Y; Sorkhabi, R (2015)Achondroplasia is an autosomal dominant congenital disorder of enchondral ossification. It is clinically characterized by low stature, craniofacial deformity, and vertebral malformation. Associated ophthalmic features ...