Monte Carlo dose calculations for a 6-MV photon beam in a thorax phantom

Thumbnail
Date
2006
Author
Farajollahi, A
Mesbahi, A
Metadata
Show full item record
Abstract
Purpose. In this study we evaluated the accuracy of the Monte Carlo (MC) and effective path length (EPL) methods for dose calculations in the inhomogeneous thorax phantom. Materials and methods. The Philips SL 75/5 linear accelerator head was modeled using the MCNP4C Monte Carlo code. An anatomic inhomogeneous thorax phantom was irradiated with a 6-MV photon beam, and the doses along points of the central axis of the beam were measured by a small ionization chamber. The central axis relative dose was calculated by the MCNP4C code and the EPL method in a conventional treatment planning system. The results of calculations and measurements were compared. Results. For all measured points on the thorax phantom the results of the MC method were in agreement with the actual measurement (local difference was less than 2%). For the EPL method, the amount of error was dependent on the field size and the point location in the phantom. The maximum error was +19.5 and +26.8 for field sizes of 10 -- 10 and 5 -- 5 cm2 for lateral irradiation. Conclusion. Our study showed large, unacceptable errors for EPL calculations in the lung for both field sizes. The accuracy of the MC method was better than the recommended value of 3%. Thus, application of this method is strongly recommended for lung dose calculations, especially for small field sizes. © 2006 Japan Radiological Society.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/56930
Collections
  • Published Articles

Related items

Showing items related by title, author, creator and subject.

  • Dose attenuation effect of hip prostheses in a 9-MV photon beam: Commercial treatment planning system versus Monte Carlo calculations 

    Mesbahi, A; Nejad, FS (2007)
    Purpose. The purpose of this study was to investigate the dosimetric effect of various hip prostheses on pelvis lateral fields treated by a 9-MV photon beam using Monte Carlo (MC) and effective path-length (EPL) methods. ...
  • Optical computed tomography in PRESAGE three-dimensional dosimetry: Challenges and prospective 

    Khezerloo, D; Nedaie, H; Farhood, B; Zirak, A; Takavar, A; Banaee, N; Ahmadalidokht, I; Kron, T (2017)
    With the advent of new complex but precise radiotherapy techniques, the demands for an accurate, feasible three-dimensional (3D) dosimetry system have been increased. A 3D dosimeter system generally should not only have ...
  • Collimator and energy window optimization for 90Y bremsstrahlung SPECT imaging: A SIMIND Monte Carlo study 

    Roshan, HR; Mahmoudian, B; Gharepapagh, E; Azarm, A; Pirayesh Islamian, J (2016)
    Treatment efficacy of radioembolization using Yttrium-90 (90Y) microspheres is assessed by the 90Y bremsstrahlung single photon emission computed tomography (SPECT) imaging following radioembolization. The radioisotopic ...

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of KR-TBZMEDCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV