Dosimetric properties of a flattening filter-free 6-MV photon beam: A Monte Carlo study
Abstract
Purpose. The dosimetric features of an unflattened 6-MV photon beam of an Elekta SL-25 linac was calculated by the Monte Carlo (MC) method. Material and methods. The head of the Elekta SL-25 linac was simulated using the MCNP4C MC code. The accuracy of the model was evaluated using measured dosimetric features, including depth dose values and dose profiles in a water phantom. The flattening filter was then removed, and beam dosimetric properties were calculated by the MC method and compared with those of the flattened photon beam. Results. Our results showed a significant (twofold) increase in the dose rate for all field sizes. Also, the photon beam spectra for an unflattened beam were softer, which led to a steeper reduction in depth doses. The decrease in the out-of-field dose and increase in the contamination electrons and a buildup region dose were the other consequences of removing the flattening filter. Conclusion. Our study revealed that, for recent radiotherapy techniques, the use of multileaf collimators for beam shaping removing the flattening filter could offer some advantages, including an increased dose rate and decreased out-of-field dose. é 2007 Japan Radiological Society.
Collections
Related items
Showing items related by title, author, creator and subject.
-
Collimator and energy window optimization for 90Y bremsstrahlung SPECT imaging: A SIMIND Monte Carlo study
Roshan, HR; Mahmoudian, B; Gharepapagh, E; Azarm, A; Pirayesh Islamian, J (2016)Treatment efficacy of radioembolization using Yttrium-90 (90Y) microspheres is assessed by the 90Y bremsstrahlung single photon emission computed tomography (SPECT) imaging following radioembolization. The radioisotopic ... -
Pulmonary embolism in pregnant patients: Assessing organ dose to pregnant phantom and its fetus during lung imaging: Assessing
Motavalli, LR; Hoseinian Azghadi, E; Miri Hakimabad, H; Akhlaghi, P (2017)Purpose: The purpose of this study was to provide updated radiation dose from diagnostic exams performed for pregnant patients suspected of pulmonary embolism (PE) using the recently developed BREP phantoms of pregnant ... -
Evaluation of the effect of temperature variation on response of PRESAGEآ® dosimeter
Farhood, B; Khezerloo, D; Zadeh, T; Nedaie, H; Hamrahi, D; Khezerloo, N (2017)Introduction: Many factors, such as PRESAGE آ® composition, dose rate, energy, and type of radiation, temperature, etc., may effect on PRESAGE آ® dosimeter response. The aim of this study was investigating the effect of ...