JavaScript is disabled for your browser. Some features of this site may not work without it.

Dose attenuation effect of hip prostheses in a 9-MV photon beam: Commercial treatment planning system versus Monte Carlo calculations

Thumbnail
Date
2007
Author
Mesbahi, A
Nejad, FS
Metadata
Show full item record
Abstract
Purpose. The purpose of this study was to investigate the dosimetric effect of various hip prostheses on pelvis lateral fields treated by a 9-MV photon beam using Monte Carlo (MC) and effective path-length (EPL) methods. Material and methods. The head of the Neptun 10 pc linac was simulated using the MCNP4C MC code. The accuracy of the MC model was evaluated using measured dosimetric features including depth dose values and dose profiles in a water phantom. The Alfard treatment planning system (TPS) was used for EPL calculations. A virtual water phantom with dimensions of 30 أ— 30 أ— 30 cm3 and a cube with dimensions of 4 أ— 4 أ— 4 cm3 made of various metals centered in 12 cm depth was used for MC and EPL calculations. Various materials including titanium, Co-Cr-Mo, and steel alloys were used as hip prostheses. Results. Our results showed significant attenuation in absorbed dose for points after and inside the prostheses. Attenuations of 32%, 54% and 55% were seen for titanium, Co-Cr-Mo, and steel alloys, respectively, at a distance of 5 cm from the prosthesis. Considerable dose increase (up to 18%) was found at the water-prosthesis interface due to back-scattered electrons using the MC method. The results of EPL calculations for the titanium implant were comparable to the MC calculations. This method, however, was not able to predict the interface effect or calculate accurately the absorbed dose in the presence of the Co-Cr-Mo and steel prostheses. Conclusion. The dose perturbation effect of hip prostheses is significant and cannot be predicted accurately by the EPL method for Co-Cr-Mo or steel prostheses. The use of MC-based TPS is recommended for treatments requiring fields passing through hip prostheses. é 2007 Japan Radiological Society.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/53584
Collections
  • Published Articles

Related items

Showing items related by title, author, creator and subject.

  • Monte Carlo dose calculations for a 6-MV photon beam in a thorax phantom 

    Farajollahi, A; Mesbahi, A (2006)
    Purpose. In this study we evaluated the accuracy of the Monte Carlo (MC) and effective path length (EPL) methods for dose calculations in the inhomogeneous thorax phantom. Materials and methods. The Philips SL 75/5 linear ...
  • Optical computed tomography in PRESAGE three-dimensional dosimetry: Challenges and prospective 

    Khezerloo, D; Nedaie, H; Farhood, B; Zirak, A; Takavar, A; Banaee, N; Ahmadalidokht, I; Kron, T (2017)
    With the advent of new complex but precise radiotherapy techniques, the demands for an accurate, feasible three-dimensional (3D) dosimetry system have been increased. A 3D dosimeter system generally should not only have ...
  • Collimator and energy window optimization for 90Y bremsstrahlung SPECT imaging: A SIMIND Monte Carlo study 

    Roshan, HR; Mahmoudian, B; Gharepapagh, E; Azarm, A; Pirayesh Islamian, J (2016)
    Treatment efficacy of radioembolization using Yttrium-90 (90Y) microspheres is assessed by the 90Y bremsstrahlung single photon emission computed tomography (SPECT) imaging following radioembolization. The radioisotopic ...

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of KR-TBZMEDCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV