JavaScript is disabled for your browser. Some features of this site may not work without it.

Comparison between the accuracy of NovApex apex locator and radiographs in determining radiographic apex

Thumbnail
View/Open
2072-Article Text-5810-1-10-20110316.pdf (5.892Mb)
Date
2011
Author
Shahi, S
Rahimi, S
Milani, AS
Jafarabadi, MA
Naghsh, GRD
Metadata
Show full item record
Abstract
INTRODUCTION: Determination of the canal working length with radiographs has many drawbacks. Electronic apex locators have been developed to overcome some of these problems. Recently, a newly designed apex locator called NovApex has been introduced. All the studies conducted to determine the accuracy of NovApex have been carried out in-vitro on extracted teeth. The aim of this in vivo study was to evaluate the accuracy of NovApex compared with traditional radiographic method. MATERIALS & METHODS: Twenty-five patients whose lower molars that were candidates for extraction were selected. The teeth were accessed, and the radiographic working length was determined by measuring the length of the initial file 0.5mm short of the radiographic apex. Then, NovApex apex locator was used to measure the electronic working length. Subsequently, the tooth was extracted, and the actual working length was measured by introducing a size #15 K-file into each canal until the file tip was visible at the apex, then 1.5mm was subtracted to attain the working length. Cohen's Kappa was computed for each of the methods versus actual working length as a measure of reliability. The accuracies were compared using Chi-square test. RESULTS: The accuracy of NovApex apex locator and radiographic method in detecting the apical end point within آ±0.5mm was 74.7% and 68%, respectively; this was not significantly different (P<0.001). CONCLUSION: The NovApex apex locator is useful in detecting the apical end point with the accuracy similar to radiographic method. However, neither technique is fully reliable in detecting the apical end point of the canal.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/53118
Collections
  • Published Articles

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of KR-TBZMEDCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV