Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization

Thumbnail
View/Open
medoral-17-e331.pdf (642.7Kb)
Date
2012
Author
Shahi, S
Mokhtari, H
Rahimi, S
Shiezadeh, V
Ashasi, H
Abdolrahimi, M
Foroughreyhani, M
Metadata
Show full item record
Abstract
Aim: The aim of the present study was to electrochemically evaluate corrosion resistance of RaCe and Mtwo files after repeated sterilization and preparation procedures. Study Design: A total of 450 rotary files were used. In the working groups, 72 files from each file type were distributed into 4 groups. RaCe and Mtwo files were used to prepare one root canal of the mesial root of extracted human mandibular first molars. The procedure was repeated to prepare 2 to 8 canals. The following irrigation solutions were used: group 1, RaCe files with 2.5% NaOCl; group 2, RaCe files with normal saline; group 3, Mtwo files with 2.5% NaOCl; and group 4, Mtwo files with normal saline in the manner described. In autoclave groups, 72 files from each file type were evenly distributed into 2 groups. Files were used for a cycle of sterilization without the use of files for root canal preparation. Nine new unused files from each file type were used as controls. Then the instruments were sent for corrosion assessment. Mann-Whitney U and Wilcoxon tests were used for independent and dependent groups, respectively. Results: Statistical analysis indicated that there were significant differences in corrosion resistance of files associated with working and autoclave groups between RaCe and Mtwo file types (p<0.001). Conclusions: Corrosion resistance of #25, #30, and #35 Mtwo files is significantly higher than that in RaCe files with similar sizes.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/49821
Collections
  • Published Articles

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of KR-TBZMEDCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV