• English
    • Persian
  • Persian 
    • English
    • Persian
  • ورود
مشاهده آیتم 
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
JavaScript is disabled for your browser. Some features of this site may not work without it.

Development and validation of a rapid and sensitive gas chromatographic method for the analysis of some phenolic compounds in vegetable oils

Thumbnail
تاریخ
2014
نویسنده
Farajzadeh, MA
Yadeghari, A
Khoshmaram, L
Ghorbanpour, H
Metadata
نمایش پرونده کامل آیتم
چکیده
A new method based on simultaneous derivatization and air-assisted liquid-liquid microextraction (AALLME) is developed for the determination of some phenolic compounds in different oils. In this method, the analytes are extracted from the oil samples by NaOH solution, then a few mu L of butyl chloroformate and carbon tetrachloride are injected into the NaOH solution containing the extracted analytes, and the resulting mixture is sucked into a syringe and injected several times into a test tube with a conical base. After centrifugation of the resulting cloudy solution, the fine droplets of the organic phase containing the derivatized phenols are precipitated at the bottom of the tube. Then, 1 mu L of the settled phase is injected into a gas chromatograph with flame ionization detection (GC-FID). The effects of extraction solvent type, derivatization agent and extraction solvent volumes, number of extractions and reaction time on the extraction efficiency were investigated. Under the optimum conditions, the enrichment factors (EF), extraction recoveries (ER), and enhancement factors (EnF) were high and ranged between 572-991, 60-109%, and 497-1471, respectively. The calibration graphs were linear in the concentration range of 3-10 000 mu g L-1. Relative standard deviations (RSD, %) for the extraction of each of the selected phenols were in the ranges of 2-4% for intra-day (n 6) and 3-5% (n 5) for inter-day precision for a concentration of 200 mu g L-1 of each analyte. Limits of detection (LOD) were in the range of 1-2 mu g L-1. Various oil samples, including olive oil, virgin olive oil, sunflower oil, and colza oil, were successfully analyzed by the proposed method.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/48893
Collections
  • Published Articles

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV