• English
    • Persian
  • English 
    • English
    • Persian
  • Login
View Item 
  •   KR-TBZMED Home
  • TBZMED Published Academics Works
  • Published Articles
  • View Item
  •   KR-TBZMED Home
  • TBZMED Published Academics Works
  • Published Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

The Efficacy and Complications of 2-Hole 3.5 mm Reconstruction Plates and 4 mm Noncanulated Cancellous Screws for Temporary Hemiepiphysiodesis Around the Knee

Thumbnail
Date
2014
Author
Aslani, H
Panjavy, B
Bashy, RHZ
Tabrizi, A
Nazari, B
Metadata
Show full item record
Abstract
Background: Persistent angular deformities around the knee can lead to growth-plate damage in childhood and osteoarthritis in adulthood. The treatment options include osteotomy and hemiepiphysiodesis. Tension-band plate hemiepiphysiodesis with 8-plate is an effective way to correct these deformities. However, its high cost makes it less available in many countries. In the present series, we have used 3.5 mm reconstruction plates for tension-band temporary hemiepiphysiodesis. Methods: Twenty-one patients with bilateral angular deformities of the knee (42 extremities) underwent temporary hemiepiphysiodesis with 3.5 mm reconstruction plates. The diagnosis, BMI, weight, amount of correction of the deformity age, and device failure were analyzed. The mean follow-up period after plate removal was 17 months (ranging from 8 to 24 mo). Results: The mean age of the patients was 10 years and 3 months (+/- 2 y and 10 mo). Complete correction of the deformities was achieved in 86% of patients. Of the 58 plate and screw constructs, 10% had screw breakage. Patients with genu valgum had 2 screw failures (6.25%), but in the genu varum group there were 4 screw failures (40%). Of the 3 patients who did not have complete correction of the deformities, 2 had mucopolysaccharidosis and 1 was nearing skeletal maturity (16 y old). The age of the patient, body weight, BMI, and degrees of angulation did not have any statistically significant correlation with the screw failure. Screw failures in female patients were more common than in male patients. All implant failures occurred in idiopathic patients. Conclusions: The efficacy of 3.5 mm reconstruction plates for temporary hemiepiphysiodesis around the knee is similar to that of 8-plates. However, the reconstruction plates have a lower cost and are easily available. Noncanulated 3.5 or 4.5 mm cortical screws seem to be superior to 4 mm noncanulated cancellous screws.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/48669
Collections
  • Published Articles

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of KR-TBZMEDCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV