• English
    • Persian
  • Persian 
    • English
    • Persian
  • ورود
مشاهده آیتم 
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
JavaScript is disabled for your browser. Some features of this site may not work without it.

Frying oils quality control: necessity for new approach of supervision

Thumbnail
تاریخ
2018
نویسنده
Ahmadi, E
Mosaferi, M
Nikniaz, L
Tabrizi, JS
Jafarabadi, MA
Safari, G
Bargar, M
Metadata
نمایش پرونده کامل آیتم
چکیده
Purpose - The purpose of this paper is to investigate the quality of the frying oil used in restaurants, fast food establishments, and confectionary stores. The compliance of used frying oils with the quality standards as determined by the peroxide value (PV) and the total polar materials (TPMs) is investigated by analyzing 375 samples of oil. Design/methodology/approach - The PV was measured according to the national standard procedure number 4179, while the TPM was determined using a Testo 270 cooking oil tester. Frying oils with a PVW5 mEq/kg and a TPMW25 percent were considered to be non-edible. For a comparison of groups, the Mann-Whitney and Spearman correlation tests were used, and po0.05 was considered significant. Findings - The maximum TPM and PV recorded for frying oils in fast food restaurants were 97.5 percent and 77.9 mEq/kg, respectively. The results also revealed that 60 percent of samples were non-edible according to the TPM, while 58.9 percent of the oil samples were non-edible because of the PV. TPM and PV correlated well with each other (r = 0.99, p<0.001) and with oil replacement intervals (r = 0.90, p<0.001). The relationship between the TPM and PV was stronger in the polynomial model than the linear model. The following equation was obtained: peroxide (mEq/kg oil) = 0.0043 TPM2 (%)+0.1587 TPM (%)-0.6152. Originality/value - Considering the current limitations in official supervision by health authority, on-site self-monitoring of the TPM using the Testo 270 cooking oil tester by sellers as a solution seems a new approach. Food stores, restaurants, and confectionary stores should be equipped with TPM analyzers to determine the quality of the frying oil and the timely replacement of non-edible oils.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/44831
Collections
  • Published Articles

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV