• English
    • Persian
  • English 
    • English
    • Persian
  • Login
View Item 
  •   KR-TBZMED Home
  • TBZMED Published Academics Works
  • Published Articles
  • View Item
  •   KR-TBZMED Home
  • TBZMED Published Academics Works
  • Published Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

An Innovative Nanosorbent Based on ZnO@Ag2O@Fe3O4 Nanocomposite- for Extraction and Preconcentration of Cd(II) Ions from Water Samples

Thumbnail
Date
2018
Author
Abdolmohammad-Zadeh, H
Rahimpour, E
Bahramzadeh, S
Metadata
Show full item record
Abstract
In this study, a ZnO@Ag2O@Fe3O4 nanocomposite as an innovative magnetic solid phase extraction agent is introduced. The structural and morphological properties of the as-prepared nano-sorbent were characterized using X-ray diffraction analysis, Fourier transform infrared spectroscopy, field emission scanning electron microscopy and nitrogen adsorption-desorption techniques. The synthesized magnetic nano-sorbent was applied for extraction and pre-concentration of Cd(II) ions from water samples. The as-prepared nano-sorbent with the magnetism property was easily manipulated by a magnet. Factors affecting the extraction of the Cd(II) ions from aqueous solutions were investigated and optimized conditions were reported. Under optimum conditions, linear concentration range of 0.1-10 ng ml(-1) with a correlation coefficient of 0.9918 was obtained for Cd(II) ions. The detection limit and enrichment factor for cadmium are 0.03 ng ml(-1) and 200, respectively. The intra-and inter-day relative standard deviations (at 4 ng ml(-1) Cd(II) ion concentration and n = 6) were found to be 1.8 and 2.6%, respectively. The maximum sorption capacity of the nano-sorbent for cadmium was 48 mg g(-1). The accuracy of the method was checked by the analysis of the standard reference material NIST SRM 1643e, and successfully applied to determine cadmium in several water and wastewater samples with relative recovery values in the range of 98-102% for the spiked samples.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/44264
Collections
  • Published Articles

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of KR-TBZMEDCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV