• English
    • Persian
  • Persian 
    • English
    • Persian
  • ورود
مشاهده آیتم 
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
JavaScript is disabled for your browser. Some features of this site may not work without it.

The effect of disinfection by spray atomization on dimensional accuracy of condensation silicone impressions.

Thumbnail
تاریخ
2010
نویسنده
Saleh Saber, F
Abolfazli, N
Kohsoltani, M
Metadata
نمایش پرونده کامل آیتم
چکیده
The condensation silicone impression materials are available, but there is little knowledge of their accuracy after disinfection. The objective of this study was to evaluate the effect of the disinfection by spray atomization on dimensional accuracy of condensation silicone impressions.Impressions were made on a stainless steel master model containing a simulated two complete crown preparation with an edentulous space interposed using Spidex® and Rapid® impression materials. 44 impressions were made with each material, of which 16 were disinfected with 5.25% sodium hypochlorite, 16 were disinfected with 10% iodophor and 12 were not disinfected. Three dimensional measurements of working casts, including interpreparation distance, height, and diameter, were calculated using a measuring microscope graduated at 0.001 mm. Dimensional changes (mm) between the disinfected and non-disinfected working casts were compared. One-way analysis of variance (ANOVA) was employed to analyze the data (?=0.05).Disinfection of each condensation silicone material by spraying atomization with two different disinfectant material resulted in significant change in interpreparation distance (p<0.05). Changes in height and diameter were only significant in Spidex® impressions (p<0.05).Significant changes in the mean dimensions were seen as a result of disinfection by spraying; however, the dimensional changes do not seem great enough to cause critical positional distortion of teeth when fixed partial denture restorations are made.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/43265
Collections
  • Published Articles

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV