• English
    • Persian
  • English 
    • English
    • Persian
  • Login
View Item 
  •   KR-TBZMED Home
  • TBZMED Published Academics Works
  • Published Articles
  • View Item
  •   KR-TBZMED Home
  • TBZMED Published Academics Works
  • Published Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Effect of Abutment Height on Retention of Single Cement-retained, Wide- and Narrow-platform Implant-supported Restorations.

Thumbnail
Date
2012
Author
Saleh Saber, F
Abolfazli, N
Nuroloyuni, S
Khodabakhsh, S
Bahrami, M
Nahidi, R
Zeighami, S
Metadata
Show full item record
Abstract
In contrast to prepared natural dentin abutments,little is known concerning factors influencing the retention of fixed prostheses cemented to implant abutments. The aim of this study was to investigate the effect of im-plant abutment height on the retention of single castings cemented to wide and narrow platform implant abutments.Thirty-six parallel-sided abutments (Biohorizon Straight Abutment) of narrow platform (NP) and wide platform (WP) sizes with their analogs were used. In each group of platform size, abutments were prepared with axial wall heights of 5, 4, 3, 2 mm (n=9). On the whole 72 castings were constructed, which incorporated an attachment to allow removal. Castings were cemented to abutments with TempBond®. A uniaxial tensile force was applied to the crown using an Instron machine until cement failure occurred. Analysis of variance of the models were fit to determine the effect of height of abutment of the restorations on the mean tensile strength (?=0.05).The mean peak removal force for corresponding abutments was significantly different (P < 0.05): (1) with plat-form sizes: WP > NP; (2) with alteration of axial wall height for NP: 5 mm > 4 mm > 3 mm = 2 mm and for WP: 5 mm > 4 mm = 3 mm = 2 mm.The retention of NP cement-retained restorations is influenced by the wall height but not in same manner as WP. Restorations of narrow-platform size with longer abutment exhibited higher tensile resistance to dislodgement.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/42577
Collections
  • Published Articles

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of KR-TBZMEDCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV