• English
    • Persian
  • Persian 
    • English
    • Persian
  • ورود
مشاهده آیتم 
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
  •   صفحه اصلی مخزن دانش
  • TBZMED Published Academics Works
  • Published Articles
  • مشاهده آیتم
JavaScript is disabled for your browser. Some features of this site may not work without it.

Effect of artificial anisometropia in dominant and nondominant eyes on stereoacuity.

Thumbnail
تاریخ
2017
نویسنده
Nabie, R
Andalib, D
Amir-Aslanzadeh, S
Khojasteh, H
Metadata
نمایش پرونده کامل آیتم
چکیده
To evaluate the effect of artificial anisometropia in dominant and nondominant eyes on stereoacuity.In this descriptive analytic study, 60 healthy adult volunteers 18-37 years of age (mean age: 25.58 years) without any ocular disease were enrolled at Tabriz Nikookari eye hospital over a 1-year period. Anisometropia (unilateral myopia) was induced by placing trial lenses over the dominant and nondominant eyes in 1-diopter (D) increments ranging from 1 to 3 D. Stereoacuity was measured using the TNO, Randot, and Titmus stereotests and values were converted into Napierian logarithm (ln) and compared between the 2 eyes.Of the 60 adults (25 male and 35 female subjects), the right eye was dominant in 49 (81.7%) of the cases. Stereoacuity levels were reduced proportionately to the degree of anisometropia in all participants. Mean stereoacuity was 4.3, 5.5, and 7.4 ln for dominant eyes and 4.1, 5.4, and 7.3 ln for nondominant eyes using the TNO test by applying 1, 2, and 3 D lenses, respectively (p > 0.05). Corresponding values were 3.5, 4.6, and 6.6 ln for dominant eyes and 3.4, 4.6, and 6.5 ln for nondominant eyes by the circles subcategory of Randot test, respectively (p > 0.05). The scores were 3.8, 4.7, and 6.5 ln for dominant eyes and 3.8, 4.7, and 6.4 ln for nondominant eyes by the circles subcategory of Titmus test, respectively (p > 0.05).Artificial anisometropia could reduce stereoacuity. However, ocular dominance has no effect on the amount of stereoacuity reduction.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/38841
Collections
  • Published Articles

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV
 

 

مرور

همه مخزنجامعه ها و مجموعه هابراساس تاریخ انتشارنویسنده هاعنوانهاموضوعاین مجموعهبراساس تاریخ انتشارنویسنده هاعنوانهاموضوع

حساب من

ورودثبت نام

مخزن دانش دانشگاه علوم پزشکی تبریز در نرم افزار دی اسپیس، کپی رایت 2018 ©  
تماس با ما | Send Feedback
Theme by 
Atmire NV