Abstract
The purpose of this study was to assess the diagnostic usefulness of ultrasonography (US) in intussusception in children and determine whether color doppler sonography (CDS) can predict bowel viability and reducibility. US were used to examine 75 children in whom the presence of intussusception was clinically suspected. CDS was performed in 75 patients with proved intussusception with US. CDS indicated blood flow in 70 of 75 cases of intussusception; nonsurgical reduction was achieved in 46 (61.4%) of 75 cases and 29 patients (38.6%) underwent surgical operation. 4 of 5 patients who had no color doppler signal underwent segmental resection. 3 of 24 patients who had color doppler signal underwent segmental resection. The difference in resection rates based on blood flow was statistically significant (p=0.007).,
تعیین دقت سونوگرافی کالر داپلر در مشخص کردن میزان Viability روده درگیر و مشخص کردن احتمال نیاز به مداخله جراحی هدف این مطالعه می باشد.75 بیمار مبتلا به انواژیناسیون در ابتدا توسط سونوگرافی و سپس توسط کالر داپلر بررسی شدند تا قدرت تشخیص و پیش بینی این ابزار ارزیابی گردد.کالر داپلر وجود جریان خون در ناحیه انواژیناسیون را در 70 بیمار از 75 بیمار شرکت کننده، تشخیص داد. از این تعداد 46 بیمار (4/61%) تحت درمان جااندازی غیرجراحی قرار گرفتند و 29 بیمار (6/38%) تحت جراحی قرار گرفتند. 4 بیمار از 5 بیماری که کالر داپلر در آن جریان خون نشان نداد، تحت رزکسیون روده ای قرار گرفتند و از 24 بیمار باقیمانده تنها برای 3 مورد رزکسیون روده ای انجام شد که این اختلاف از نظر آزمونهای آماری انجام گرفته، کاملا معنی دار بوده است (007/0=p).