dc.description.abstract | Abstract:
Background: retention is an essential factor in the success of cement-retained implant supported restorations. Achieving adequate retention for short abutments (<4 mm) remains major challenge.
Purpose: this study was designed to investigate the effect of modifications of short abutment in order to increase retention.
Materials and methods: 72 implant abutments were designed and milled and divided in 6 group (12 abutment each group).a control group without modification , one axial wall removal , two opposing wall , axial groove , frustum groove and circumferential groove. 72 zirconia crown were prepared using ( CAD/CAM ) to fit all abutments. All crowns were cemented with dual cure resin cement. A pull -out test using universal machine test was applied until separation
Results: the main retentive value : first group 155/93 N , second group 194/33 N, third group 201/94 N , forth group 198/55N , fifth group 191/65 N and sixth group 220/05 N. the retention of group with circumferential groove and removal of two opposing wall was significantly higher than control group ( P< 0/05)
Conclusion : According to the results of study , modifications of abutment design including circumferential groove and removal of opposing wall improve the retention of zirconia restoration cemented to short abutments. | en_US |
dc.language.iso | fa | en_US |
dc.publisher | Tabriz University of Medical Sciences, School of Dentistry | en_US |
dc.relation.isversionof | https://dspace.tbzmed.ac.ir:443/xmlui/handle/123456789/72076 | |
dc.subject | abutment, implant supported dental prothesis , retention, dental implant abutment design , zirconia | en_US |
dc.title | Effect of axial wall modification of short titanium abutments on the retention of implant supported zirconia crowns | en_US |
dc.type | Thesis | en_US |
dc.contributor.supervisor | Hafez Qoran, Ali | |
dc.identifier.docno | 605132 | en_US |
dc.identifier.callno | 69462* | en_US |
dc.contributor.department | prosthodontics | en_US |
dc.description.discipline | prosthdontics | en_US |
dc.description.degree | MSCD | en_US |
dc.citation.reviewer | Ghaffari, Tahereh | |
dc.citation.reviewer | Yasamineh, Neda | |
dc.citation.reviewer | Mahbob, Farhangh | |
dc.citation.reviewer | Fakhrzadeh, Vahid | |