Show simple item record

dc.contributor.advisorSarvari, Rana
dc.contributor.authorAlah Gholi Poor, Ehsan
dc.date.accessioned2023-01-18T08:30:49Z
dc.date.available2023-01-18T08:30:49Z
dc.date.issued2022en_US
dc.identifier.urihttps://dspace.tbzmed.ac.ir:443/xmlui/handle/123456789/68031
dc.description.abstractAbstract Background and purpose: The aim of this study is to investigate the possibility of hydroxyapatite, graphene oxide and polyethyleneimine coating on titanium alloy implants and their biocompatibility. Materials and methods: Thirty-five titanium samples were cut to a diameter and length of 10 mm. After grounding samples were sanded with 1200 grade sandpaper in water, and washed with acid, ethanol, and acetone. Hydroxyapatite was coated by electrophoretic deposition on titanium discs and the coating was confirmed by EDS, SEM and XRD tests. Then graphene oxide was grafted on hydroxyapatite by esterification reaction and the resulting products were confirmed by EDS, SEM and XRD spectroscopy. In the next step, polyethyleneimine was grafted on coated graphene oxide and hydroxyapatite and the resulting product was analyzed and confirmed by EDS, SEM and XRD. The biocompatibility of the composite coating on the implant surface was checked by MTT assay. For data analysis, shapiro wilk and tukey tests was used to check the normality of the data, one-way analysis of variance and spss version 24 software. Results: SEM images showed uniform coverage of hydroxyapatite particles and graphene oxide sheets with a thickness of 120-130 nm. The morphology of titanium coated with hydroxyapatite-graphene oxide- polyethyleneimine also has almost uniform parts with porosities. EDS evaluation indicates Ca and P elements in the titanium coated with hydroxyapatite and C and O elements in the sample coated with graphene oxide. In the case of titanium coated with polyethyleneimine, the amount of C and O elements is still high, and N , P and Ca elements are seen in the composition. Evaluation by XRD confirmed the crystalline nature of each stage of the coating. Biocompatibility evaluation did not show a significant difference between the toxicity of uncoated titanium sample and titanium coated with hydroxyapatite-graphene oxide- polyethyleneimine (P value>0.05). Conclusion: Covering titanium implants with hydroxyapatite by electrophoretic deposition and grafting graphene oxide and polyethyleneimine on it produces a titanium sample with high biocompatibility. Keywords: implant coat, graphene oxide, hydroxyapatite, polyethyleneimineen_US
dc.language.isofaen_US
dc.publisherTabriz University of Medical Sciences, Faculty of Dentistryen_US
dc.relation.isversionofhttps://dspace.tbzmed.ac.ir:443/xmlui/handle/123456789/68030
dc.subjectimplant coat, graphene oxide, hydroxyapatite, polyethyleneimineen_US
dc.titleEvaluation of the probability of coating hydroxyapatite, graphene oxide and polyethyleneimine on titanium implants and its biocompatibilityen_US
dc.typeThesisen_US
dc.contributor.supervisorSadr Haghighi, Amirhuman
dc.contributor.supervisorPooyafar, Vahid
dc.identifier.docno603885en_US
dc.identifier.callno67450en_US
dc.contributor.departmentOrthodonticsen_US
dc.description.disciplineDentistryen_US
dc.description.degreeD.D.Sen_US
dc.citation.reviewerRavadgar, Mehdi
dc.citation.reviewerKahyaee Aghdam, Mina
dc.citation.reviewerMohammadi Shayan, Arman


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record