Show simple item record

dc.contributor.advisorBahari, Mahmud
dc.contributor.authorNaserneysari, Ferdos
dc.date.accessioned2023-01-03T09:27:54Z
dc.date.available2023-01-03T09:27:54Z
dc.date.issued2022en_US
dc.identifier.urihttps://dspace.tbzmed.ac.ir:443/xmlui/handle/123456789/67978
dc.description.abstractTitle: Effect of preheating on the microtensile bond strength of the bulk-fill resin composite to dentin of the floor of class 1 cavities. Purpose:Due to the lack of the articles about the effect of preheating on the microtensile bond strength of the bulk-fill resin composite in cavities with high C-Factor, purpose of this study was to evaluate the effect of preheating on the microtensile bond strength of the bulk-fill resin composite to dentin of the floor of class 1 cavities. Material and methods: 36 extracted sound human lower third molars with similar dimensions were collected, cleaned and stored. The cusps were sectioned to form a flat occlusal surface. After etching and bonding, a 1mm thick layer of Filtek Z250 microhybrid resin composite was applied on occlusal surface. In the middle of the occlusal surface a class 1 cavity (3.5×3.5×4 mm) was prepared in a way that pulpal floor was placed in middentin. The teeth were randomly divided into two groups (n=18).The tubes of X-tra fil composites were stored in distilled water with temperatures of 23˚C and 60˚C for 30 minutes, then it was packed in cavities. A 500 round thermocycling procedure was carried out with 5 and 55˚C. Then every 3 teeth were mounted in a block of self-cure acrylic resin and the blocks were glued to the plates, afterword they were sectioned into 1mm × 1mm species with a trimming device under water coolant, providing at least 3 species per tooth, therefore there were 110 species in total. The species were glued at the end of the microtensile testing machine’s jig and they were loaded in tension until breaking. The load at failure was recorded in Newton. For determination of mean difference of preheating on microtensile bond strength, independent T test was used (p<0.05). Results: The independent T test showed that there was significantly statistical difference between preheating and non preheating groups (p=0.002). The meaning of the microtensile bond strength in preheated group significantly increased compared to other group.en_US
dc.language.isofaen_US
dc.publisherTabriz University of Medical Sciences, School of Dentistryen_US
dc.relation.isversionofhttps://dspace.tbzmed.ac.ir:443/xmlui/handle/123456789/67977
dc.subjectresin compositeen_US
dc.subjectpreheatingen_US
dc.subjectbulkfillen_US
dc.subjectmicrotensile bond strengthen_US
dc.titleEffect of preheating on the microtensile bond strength of the bulk-fill resin composite to dentin of the floor of class 1 cavities.en_US
dc.typeThesisen_US
dc.contributor.supervisorDibazar, Sana
dc.identifier.docno603884en_US
dc.identifier.callno67969en_US
dc.contributor.departmentOperative dentistryen_US
dc.description.disciplineDentistryen_US
dc.description.degreeDDSen_US
dc.citation.reviewerAbed Kahnamoei, Mehdi
dc.citation.reviewerPournaghi Azar, Fatemeh
dc.citation.reviewerKahyaee Aghdam, Mina
dc.citation.reviewerEbrahimi, Mohammad esmail
dc.citation.reviewerDaneshpooy, Mehdi


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record