Show simple item record

dc.contributor.advisorDabaghi Tabrizi, Fatemeh
dc.contributor.authorWaleed Alghurabi, Khaled
dc.date.accessioned2022-08-01T06:43:44Z
dc.date.available2022-08-01T06:43:44Z
dc.date.issued2022en_US
dc.identifier.urihttp://dspace.tbzmed.ac.ir:80/xmlui/handle/123456789/66874
dc.description.abstractBackground and Aim: Light activated composite resin is considered as the choice of restorative material due to its high aesthetic demand. Various external and internal factors affect the effectiveness of polymerization, which may affect the life of the final restoration. Our aim was to investigate the effect of different curing distances on the micro flexural strength of nanohybrid composite and giomer. Materials and Methods: In this study, FiltekTM Z250 XT composite and Beautifil giomer were used. 60 rectangular specimens (6 mm * 2 mm * 1 mm) were prepared (30 samples for each composite type, 10 samples were placed in each sub- group depending on the distance from light source). Samples were light-cured at three different distances (0 mm, 2 mm and 8 mm) according to the manufacturer's instructions for each composite and kept in deionized water at 37 ° C for 24 hours. The micro flexural strength test was performed by a universal test machine at a speed of 1 mm / min. SPSS software version 17 was used for data analysis. A probability value of less than 5% was considered a significant level. Results: According to the findings of this study, the highest mean flexural strength was related to the light cure group at a distance of 0 mm. According to the results of two-way analysis of variance (Two way ANOVA), there was a significant difference between the mean micro-flexural strength at different distances of the curing (P-Value = 1.925). There was significant difference between the mean flexural strength at a distance of 0 mm and its mean at the other two distances, but there was no significant difference between 2 and 8 mm. Also, there was a statistically significant difference between the mean micro-flexural strength of the two composites and the mean micro-flexural strength of 3M Z250 composite was higher than the Shufo composite. Conclusion: According to the obtained results, in general, it can be said that by increasing the curing distance, the micro-flexural strength in both resin and giomer based composites decreases and the micro-flexural strength in Z250 composite is higher than Shufo composite.en_US
dc.language.isofaen_US
dc.publisherTabriz university of medical sciences, faculty of dentistryen_US
dc.relation.isversionofhttp://dspace.tbzmed.ac.ir:80/xmlui/handle/123456789/66873
dc.subjectMicro Flexural strength, Light cure, Composite resin, Giomeren_US
dc.titleThe effect of different curing distances on the microflexural strength of nanohybrid and giomer composite resinsen_US
dc.typeThesisen_US
dc.contributor.supervisorDaneshpooy, Mehdi
dc.identifier.docno603912en_US
dc.identifier.callno67647*en_US
dc.contributor.departmentOperative dentistryen_US
dc.description.disciplineOperative dentistryen_US
dc.description.degreeMScDen_US
dc.citation.reviewerAbed Kahnamoii, Mehdi
dc.citation.reviewerKimyaee, Sodabeh
dc.citation.reviewerKachoee, Mozhghan
dc.citation.reviewerJafari, Elmira
dc.citation.reviewerAlizadeh, Parnian
dc.citation.reviewerEbrahimi Chaharom, Mohammad Esmail
dc.citation.reviewerSavadi Oskoee, Siyavash


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record