dc.description.abstractThe aim of this study was calculating geometric uncertainties in the treatment and estimated the sufficiency of the margins employed for PTV generation in the treatment of patients undergoing head and neck cancer radiotherapy with two different techniques 3D CRT and IMRT Materials and methods We obtained weekly portal images for forty patients with 3D CRT technique and daily portal images for forty patients with IMRT technique of setup fields in anterior-posterior and lateral directions. These images were match with the reference image (DRR). The displacement of portal image from the reference image was record in X (SI), Y (LR) and Z (AP). The population systematic and random errors were calculated. Moreover, the values for the clinical to planning target volume (CTV-PTV) margins were calculated using van Herk’s formula and ICRU Report 62 recommendations, also Stroom formula. Results EPID images obtained in Anterior-posterior and lateral for any patients. The patients offset calculated by MOSAIQ software before beginning of the treat. Systematic and Random errors separately calculated by two different techniques. In 3D CRT technique, Systematic error was 1.5, 1.8and 2.0 mm in SI, LR and AP direction. also, Random error was 2.6, 2.9 and 2.9 mm in SI, LR and AP direction respectively. As well as for IMRT technique, Systematic error in SI, LR and AP direction was 1.0, 0.95 and 1.2 mm and for Random error calculated 1.8, 1.8 and 1.9 mm in SI, LR and AP direction respectively. Obtained margin from Van Herk formula for 3D CRT in tree direction SI, LR and AP respectively was 5.8, 6.7 and 7.2 mm, and for IMRT was 4.0, 3.6 and 4.5mm in SI, LR and AP direction.en_US
dc.language.isofaen_US
dc.publisherTabriz University of Medical Sciences, Faculty of Medicineen_US
dc.subjectEPIDen_US
dc.subject3D CRTen_US
dc.subjectIMRTen_US
dc.subjectCTV to PTV marginen_US
dc.subjectMOSAIQen_US
dc.titleEvaluation of setup error in patients undergoing head and neck cancer with radiotherapy techniques by IMRT and 3D CRT techniques in Specialty Reza Radiation Oncology cancer center of Mashhaden_US
dc.typeThesisen_US
dc.contributor.supervisorFarajollahi, Alireza
dc.contributor.supervisorMomennezhad, Mahdi
dc.identifier.docno609615en_US
dc.identifier.callno9615en_US
dc.description.disciplineMedical Physicsen_US
dc.description.degreeM. Sc degreeen_US


فایلهای درون آیتم

فایلهاسایزفرمتنمایش

هیچ فایل مرتبطی وجود ندارد

این آیتم در مجموعه های زیر مشاهده می شود

نمایش پرونده ساده آیتم