نمایش پرونده ساده آیتم

dc.contributor.advisorkodarian, roudabeh
dc.contributor.authorAkbarzadeh, Ayshin
dc.date.accessioned2019-09-19T05:46:32Z
dc.date.available2019-09-19T05:46:32Z
dc.date.issued2019en_US
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/60698
dc.description.abstractObjectives: Designing a high strength ceramic fixed partial denture with favorable esthetics can be a challenge for clinicians; this study aims to evaluate the effect of connector size and design on fracture resistance of monolithic zirconia fixed dental prosthesis. Materials and methods: Two groups of twenty 3-unit monolithic zirconia (Sirona inCoris TZI, Sirona Dental Systems GmbH) bridges extending from mandibular first premolar to first molar with different connector size (9mm2, 12mm2) were divided into two subgroups with different connector design (round and sharp). The specimens were subjected to 3-point bending test to obtain the fracture bearing load. The results reported using descriptive statistics (mean ± standard deviation). To compare the fracture load in two types of designs and two dimensions of the connectors simultaneously, two-way ANOVA analysis of variance was used. The significance level was considered as p <0.05. Results: The minimum failure load was related to group with 9mm2 connector dimension and sharp embrasure design 1054.4±133.89 N), and the highest mean value belongs to group with 12mm2 connector dimension and rounded embrasure design (1599.8±167.09N). Mann-Whitney U test indicated a significant difference between the mean failure load of the rounded and sharp embrasure designs in 9 mm2 connector dimension (p=0.007). However, the difference was insignificant in 12mm2 connector dimension (p=0.075). Conclusion: Sharp embrasure design is not recommended for high-stress areas with restricted occlusogingival height. Nine mm2 connector dimension for 3-unit monolithic zirconia FDP which is recommended from the manufacturer should be used more cautiously.en_US
dc.language.isoEnen_US
dc.publisherTabriz University of Medical Sciences, School of dentistryen_US
dc.relation.isversionof
dc.subjectMonolithic zirconia, Fixed partial denture, Dental ceramics, Load bearing.en_US
dc.titleEvaluation of the effect of connector size and design on flexural strength of monolithic zirconia fixed dental prosthesisen_US
dc.typeThesisen_US
dc.contributor.supervisorhafezegoran, ali
dc.identifier.docno603323en_US
dc.identifier.callno60896*en_US
dc.description.disciplinedentistryen_US
dc.description.degreeMScD Degreeen_US
dc.citation.reviewerGhaffari, Tahereh
dc.citation.reviewerMahbob, Farhangh
dc.citation.reviewerAlizadeh, Parnian
dc.citation.reviewerTorab, Ali
dc.citation.reviewerBarzeghar, Ali
dc.citation.reviewerNorizadeh, Amin
dc.citation.reviewerVahid Pakdel, Mahdi


فایلهای درون آیتم

Thumbnail

این آیتم در مجموعه های زیر مشاهده می شود

نمایش پرونده ساده آیتم