نمایش پرونده ساده آیتم

dc.contributor.advisorNegahdari, Ramin
dc.contributor.authorMortazavi milani, Ata
dc.date.accessioned2019-06-23T09:25:44Z
dc.date.available2019-06-23T09:25:44Z
dc.date.issued2019en_US
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/60092
dc.description.abstractHistory and goal: according to the effect of the different splinting materials on the fixture level implant impression (open tray technique) and the accuracy of the final cast dimensions and different view points on its best technique in dentistry, this research was conducted in order to study the effect of the fixture level implant impression (open tray) accuracy with two different splinting materials Materials and methods: in this experiential research, at first, two pieced steel index was prepared and it was poured by a self- cure acryl in the lower part of the index that imitated the jaw of the patient. Then two holes were prepared with specific intervals in the acryl and the analogs were placed in the holes and cemented in it then by the upper part of the index that plays custom trays role three casting techniques were evaluated by open tray method with two different splinting material.GC Pattern resin LS America and Jig-Gel(biodenzircise,korea) The dimensional accuracy of the prepared casts was assessed by comparing defined points on the implants analogs with similar intervals in the main model. Measuring the defined intervals was done by digital caliper with hundredths of a mm precision and the difference in measurements of the final casts was analyzed by software SPSS 17 and One Sample T-test. For paired comparison Mann-Whitney U was used. Results: splinting impression copings by GC Pattern resin without cutting and reconnecting the splint of impression copings was the most accurate splinting material. Both splinting material had same result in splinted impression copings and reconnected splint of impression copings. Conclusion: Considering that the splinted impression copings prevented impression copings movement during impression this technique had best accuracy and splinting impression copings by GC Pattern resin without cutting and reconnecting the splint of impression copings was the most accurate splinting material. Splinting impression copings by Jig-Gel as a light-cured splinting material did not make a significant effect in increasing the dimensional accuracy of the final cast. Thus the use of splinted impression copings by Jig-Gel with cutting and reconnecting splint of impression copings increased accuracy of impression. Reconnected splint of impression copings and splinted impression copings methods had similar results.en_US
dc.language.isofaen_US
dc.publisherTabriz University of Medical Sciences, School of dentistryen_US
dc.relation.isversionofhttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/60091
dc.subjectdental implant, implant impression, splinten_US
dc.titleComparison of the fixture level implant impression (open tray) accuracy with two different splinting materialsen_US
dc.typeThesisen_US
dc.contributor.supervisorBarzegar, Ali
dc.identifier.docno603210en_US
dc.identifier.callno60430en_US
dc.description.disciplinedentistryen_US
dc.description.degreedds degreeen_US
dc.citation.reviewerGhaffari, Tahereh
dc.citation.reviewerMoslehi Fard, Elnaz
dc.citation.reviewerTorab, Ali
dc.citation.reviewerParnia, Fereydon
dc.citation.reviewerGhasemi, Shima
dc.citation.reviewerPornasrollah, Alireza


فایلهای درون آیتم

Thumbnail

این آیتم در مجموعه های زیر مشاهده می شود

نمایش پرونده ساده آیتم