نمایش پرونده ساده آیتم

dc.contributor.advisorGhaemmaghami, Mehrdad
dc.contributor.authorZare, Zakie
dc.date.accessioned2018-11-19T07:58:47Z
dc.date.available2018-11-19T07:58:47Z
dc.date.issued2018en_US
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/59083
dc.description.abstractThe aim of present study was to compare of maternal satisfaction between delivery with neuraxial analgesia and natural vaginal delivery. Methods & Materials: In a cross-sectional study, 45 nulliparous women undergoing vaginal delivery without using analgesia and 45 nulliparous women undergoing vaginal delivery with neuraxial analgesia who referred to Taleghani Educational-Medical Hospital of Tabriz University of Medical Sciences, were included the study. Pain intensity based on VAS score and maternal satisfaction from delivery based on SWCH & BSS-R checklists were determined. Statistical analysis was performed using SPSS version 22 software and relationship between variables was assessed by Pearson coefficient. P-value<0.05 was considered statistically significant. Results: Mean VAS score in group without analgesia was 8.55±2.07 and in group with neuraxial analgesia was 6.24±2.02 (P=0.001). Based on SWCH and BBS-R checklists the mean of maternal satisfaction in the mothers group without analgesia were 35.37±10.85 in the range of 13 to 53 and 24.06±5.58 in the range of 15 to 37 respectively, and in the group of mothers with neuraxial analgesia were 42.00±6.13 in the range of 26 to 53 and 27.35±5.62 in the range of 12 to 37 respectively. There was an inverse association between severity of pain during labor and delivery satisfaction based on SWCH checklist (r= -0.293, P=0.005). Conclusion: Based on findings of present study, using neuraxial analgesia reduced the pain of natural childbirth and increases maternal delivery satisfaction significantlyen_US
dc.language.isofaen_US
dc.publisherTabriz University of Medical Sciences, School of Medicineen_US
dc.subjectMaternal Satisfactionen_US
dc.subjectVaginal Deliveryen_US
dc.subjectNeuraxial Analgesiaen_US
dc.titleComparison of Maternal Satisfaction between Delivery with Neuraxial Analgesia and Natural Vaginal Deliveryen_US
dc.typeThesisen_US
dc.contributor.supervisorPourfathi Nematabad, Hojjat
dc.contributor.supervisorMallah, Fatemeh
dc.identifier.docno608879en_US
dc.identifier.callno8879en_US
dc.description.disciplineAnesthesiaen_US
dc.description.degreeMD.Degreeen_US


فایلهای درون آیتم

فایلهاسایزفرمتنمایش

هیچ فایل مرتبطی وجود ندارد

این آیتم در مجموعه های زیر مشاهده می شود

نمایش پرونده ساده آیتم