Show simple item record

dc.contributor.authorMesbahi, A
dc.contributor.authorAkcay, D
dc.contributor.authorTekcan, IV
dc.contributor.authorAlikus, ZA
dc.date.accessioned2018-08-26T09:40:39Z
dc.date.available2018-08-26T09:40:39Z
dc.date.issued2017
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/58410
dc.description.abstractIntroduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomography (CBCT) images were taken after bony anatomy alignment by using two orthogonal radiographic images, as well as CBCT images. Dose distributions and dose volume histograms (DVH) for all the original and CBCT plans were obtained. Maximum, as well as mean doses and volumes of the bladder, rectum, and both femoral heads were recorded for each CBCT plan and compared with the original CT plan. For all the studied body parts, the differences in DVH between CBCT plans and original CT plan were calculated and compared. Results: Considering all the 75 CBCT images for the 15 patients, average of changes in mean doses and volumes were 17.8%, 41.8%, 7.1%, and 36.8% for the bladder and rectum, respectively. There was a significant (P < 0.05) negative correlation between mean bladder dose and volume, while a weak and positive correlation was found between mean dose and volume of rectum in our patients. Conclusion: Our results showed that changes in volumes of the bladder and rectum alter their received inter-factional mean doses. Further attention to the volume variations of the bladder and rectum during a radiotherapy course is recommended for more accurate IGRT treatment.
dc.language.isoEnglish
dc.relation.ispartofIranian Journal of Medical Physics
dc.subjectDiseases
dc.subjectDosimetry
dc.subjectPatient treatment
dc.subjectRadiotherapy
dc.subjectTomography
dc.subjectUrology
dc.subjectCone beam computed tomography image (CBCT)
dc.subjectCone-beam computed tomography
dc.subjectDose-volume histograms
dc.subjectImage-guided radiation therapy
dc.subjectNegative correlation
dc.subjectPositive correlations
dc.subjectProstate cancers
dc.subjectVolumetric modulated arc therapy
dc.subjectComputerized tomography
dc.titleThe impact of residual geometric inaccuracies on normal organ doses in image guided-radiation therapy of prostate cancer using on-board kilovoltage Cone-Beam computed tomography
dc.typeArticle
dc.citation.volume14
dc.citation.issue2
dc.citation.spage104
dc.citation.epage113
dc.citation.indexScopus
dc.identifier.DOIhttps://doi.org/10.22038/ijmp.2017.19419.1178


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record