نمایش پرونده ساده آیتم

dc.contributor.authorBeigi, M
dc.contributor.authorAfarande, F
dc.contributor.authorGhiasi, H
dc.date.accessioned2018-08-26T09:34:16Z
dc.date.available2018-08-26T09:34:16Z
dc.date.issued2016
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/57711
dc.description.abstractAim: The aim of this study was to compare two bunkers designed by only protocols recommendations and Monte Carlo (MC) based upon data derived for an 18. MV Varian 2100Clinac accelerator. Background: High energy radiation therapy is associated with fast and thermal photoneutrons. Adequate shielding against the contaminant neutron has been recommended by IAEA and NCRP new protocols. Materials and methods: The latest protocols released by the IAEA (safety report No. 47) and NCRP report No. 151 were used for the bunker designing calculations. MC method based upon data was also derived. Two bunkers using protocols and MC upon data were designed and discussed. Results: From designed door's thickness, the door designed by the MC simulation and Wu-McGinley analytical method was closer in both BPE and lead thickness. In the case of the primary and secondary barriers, MC simulation resulted in 440.11. mm for the ordinary concrete, total concrete thickness of 1709. mm was required. Calculating the same parameters value with the recommended analytical methods resulted in 1762. mm for the required thickness using 445. mm as recommended by TVL for the concrete. Additionally, for the secondary barrier the thickness of 752.05. mm was obtained. Conclusion: Our results showed MC simulation and the followed protocols recommendations in dose calculation are in good agreement in the radiation contamination dose calculation. Difference between the two analytical and MC simulation methods revealed that the application of only one method for the bunker design may lead to underestimation or overestimation in dose and shielding calculations. ط¢آ© 2015 Greater Poland Cancer Centre.
dc.language.isoEnglish
dc.relation.ispartofReports of Practical Oncology and Radiotherapy
dc.subjectconcrete
dc.subjectlead
dc.subjectpolyethylene
dc.subjectanalytic method
dc.subjectArticle
dc.subjectdosimetry
dc.subjectlinear accelerator
dc.subjectMonte Carlo method
dc.subjectphoton
dc.subjectradiation protection
dc.subjectradiation shield
dc.subjectradioactive contamination
dc.subjectWu McGinley method
dc.titleSafe bunker designing for the 18MV Varian 2100 Clinac: A comparison between Monte Carlo simulation based upon data and new protocol recommendations
dc.typeArticle
dc.citation.volume21
dc.citation.issue1
dc.citation.spage42
dc.citation.epage49
dc.citation.indexScopus
dc.identifier.DOIhttps://doi.org/10.1016/j.rpor.2015.10.003


فایلهای درون آیتم

Thumbnail

این آیتم در مجموعه های زیر مشاهده می شود

نمایش پرونده ساده آیتم