dc.description.abstractRadiation oncology has been rapidly improved by the application of new equipment and techniques. With the advent of new complex and precise radiotherapy techniques such as intensity modulated radiotherapy, stereotactic radiosurgery, and volumetric modulated arc therapy, the demand for an accurate and feasible three-dimensional (3-D) dosimetry system has increased. The most important features of a 3-D dosimeter, apart from being precise, accurate and reproducible, include also its low cost, feasibility, and availability. In 2004 a new generation of solid plastic dosimeters which demonstrate a radiochromic response to ionizing radiation was introduced. PRESAGE® plastic dosimeter lacks the limitations of previous Ferric and polymer plastic 3-D dosimeters such as diffusion, sensitivity to oxygen, fabrication problems, scanning and read out challenges. In this decade, a large number of efforts have been carried out to enhance PRESAGE® structure and scanning methods. This article attempts to review and reflect on the results of these investigations. é 2017 Elsevier Ltd
dc.language.isoEnglish
dc.relation.ispartofRadiation Physics and Chemistry
dc.subjectComputerized tomography
dc.subjectDosimetry
dc.subjectIonizing radiation
dc.subjectOncology
dc.subjectRadiotherapy
dc.subjectGel dosimetry
dc.subjectImportant features
dc.subjectIntensity-modulated radiotherapy
dc.subjectOptical CT
dc.subjectRadiation dosimeters
dc.subjectStereotactic radiosurgery
dc.subjectThreedimensional (3-d)
dc.subjectVolumetric modulated arc therapy
dc.subjectDosimeters
dc.subjectpolyurethan
dc.subjectbrachytherapy
dc.subjectdiffusion
dc.subjectdosimeter
dc.subjectdosimetry
dc.subjecthuman
dc.subjectionizing radiation
dc.subjectmeasurement accuracy
dc.subjectmeasurement precision
dc.subjectradiation dose
dc.subjectradiation response
dc.subjectreproducibility
dc.subjectReview
dc.subjectsensitivity analysis
dc.subjectstructure analysis
dc.subjectthermoluminescence dosimeter
dc.subjectthermoluminescence dosimetry
dc.subjecttreatment planning
dc.titlePRESAGE® as a solid 3-D radiation dosimeter: A review article