dc.contributor.authorKuroda, Y
dc.contributor.authorYukinaga, H
dc.contributor.authorKitano, M
dc.contributor.authorNoguchi, T
dc.contributor.authorNemati, M
dc.contributor.authorShibukawa, A
dc.contributor.authorNakagawa, T
dc.contributor.authorMatsuzaki, K
dc.date.accessioned2018-08-26T09:31:30Z
dc.date.available2018-08-26T09:31:30Z
dc.date.issued2005
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/57076
dc.description.abstractOn-line capillary isoelectric focusing-mass spectrometry (cIEF-MS) was applied to determine concentrations of peptides and proteins using angiotensin II and human tetrasialo-transferrin as the model samples. The concentration of the carrier ampholyte was optimized for both resolution and ion intensity. cIEF-MS employing 1% Pharmalyte 3-10 and a sheath liquid containing water/methanol/acetic acid (50/49/1) resolved angiotensin I and II (5 ?M each, ?pI = 0.2) at an Rs value of 2.29. The determined concentration of angiotensin II (0.1-5 ?M) well correlated (R = 0.999) with that obtained by the conventional RP-HPLC method. The limit of detection was 0.22 ?M, which was about 10 times lower than that by UV detection (2 ?M). The repeatability and accuracy were <15 and <11%, respectively. cIEF-MS was also applied to determine human tetrasialo-transferrin concentration. The good linearity (R 2 = 0.998) was also observed between the transferrin concentration (0.5-1.2 g/L) and peak area ratio (IS; ?-lactoglobulin B) with acceptable accuracy (<1.9%) and repeatability (?10% at 1 g/L). ط¢آ© 2004 Elsevier B.V. All rights reserved.
dc.language.isoEnglish
dc.relation.ispartofJournal of Pharmaceutical and Biomedical Analysis
dc.subjectacetic acid
dc.subjectampholyte
dc.subjectangiotensin
dc.subjectangiotensin I
dc.subjectbeta lactoglobulin
dc.subjectbovine serum albumin
dc.subjectcarbonate dehydratase
dc.subjection
dc.subjectlypressin
dc.subjectmethanol
dc.subjectmyoglobin
dc.subjectpeptide
dc.subjectprotein
dc.subjecttetrasialotransferrin
dc.subjecttransferrin
dc.subjectunclassified drug
dc.subjectwater
dc.subjectaccuracy
dc.subjectarticle
dc.subjectcontrolled study
dc.subjectcorrelation analysis
dc.subjecthuman
dc.subjectisoelectric focusing
dc.subjectlinear system
dc.subjectliquid
dc.subjectmass spectrometry
dc.subjectnonhuman
dc.subjectpeptide analysis
dc.subjectpriority journal
dc.subjectprotein analysis
dc.subjectquantitative analysis
dc.subjectreproducibility
dc.subjectreversed phase high performance liquid chromatography
dc.subjectultraviolet spectroscopy
dc.titleOn-line capillary isoelectric focusing-mass spectrometry for quantitative analysis of peptides and proteins
dc.typeArticle
dc.citation.volume37
dc.citation.issue3
dc.citation.spage423
dc.citation.epage428
dc.citation.indexScopus
dc.identifier.DOIhttps://doi.org/10.1016/j.jpba.2004.11.025