Show simple item record

dc.contributor.authorBilehjani, E
dc.contributor.authorFakhari, S
dc.date.accessioned2018-08-26T08:56:41Z
dc.date.available2018-08-26T08:56:41Z
dc.date.issued2009
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/54477
dc.description.abstractObjective To determine the hemodynamic response to laryngoscopy/tracheal intubation using GlideScope® videolaryngoscope in patients with ischemic heart diseases. Methods In a randomized clinical trial, 80 adult patient, candidate for coronary artery bypass graft surgery were allocated in two groups for laryngoscopy (MC=Macintosh blade or GS=GlideScope). The hemodynamic response, laryngoscopy time, success rate and complication rate were compared. Results Two patients were excluded because of long postoperative intubation period. Demographic data and airway characteristics were comparable. There was no failed intubation. Laryngoscopy time in MC group was shorter than GS group (14.50آ±8.30 versus 48.80آ±47.82 respectively, p=0.001). Stylet was used commonly and more attempts to intubation were done in GS group. Hemodynamic response to orotracheal intubation in 1, 5 and 15 min following intubation was not different between two groups. Conclusions GlideScope® technique did not have any benefit and increased laryngoscopy time, need to use stylet and required more attempts. (Rawal Med J 2009;34: 151-154).
dc.language.isoEnglish
dc.relation.ispartofRawal Medical Journal
dc.subjectdiazepam
dc.subjectfentanyl
dc.subjectmidazolam
dc.subjectmorphine sulfate
dc.subjectpromethazine
dc.subjectadult
dc.subjectarticle
dc.subjectbleeding
dc.subjectclinical trial
dc.subjectcontrolled clinical trial
dc.subjectcontrolled study
dc.subjectcoronary artery bypass graft
dc.subjectdemography
dc.subjectendotracheal intubation
dc.subjectfemale
dc.subjectglidescope videolaryngoscope
dc.subjectheart rate
dc.subjecthemodynamics
dc.subjecthuman
dc.subjectintermethod comparison
dc.subjectintubation
dc.subjectischemic heart disease
dc.subjectlaryngoscope
dc.subjectlaryngoscopy
dc.subjectmacintosh blade
dc.subjectmajor clinical study
dc.subjectmale
dc.subjectmean arterial pressure
dc.subjectmouth injury
dc.subjectpneumothorax
dc.subjectpostoperative period
dc.subjectrandomized controlled trial
dc.subjectsore throat
dc.subjecttreatment outcome
dc.titleHemodynamic response to laryngoscopy in ischemic heart disease: Macintosh blade versus glidescope® videolaryngoscope
dc.typeArticle
dc.citation.volume34
dc.citation.issue2
dc.citation.spage151
dc.citation.epage154
dc.citation.indexScopus


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record