dc.description.abstractThe present study was an attempt to investigate the effect of variation of inversion time (T I) and saturation time (T S) on the linear relationship between contrast agent concentration and signal intensity (SI) on Turbo Fast Low Angle Shot (TurboFLASH) T 1-weighted images in MRI. For this purpose, inversion recovery (IR) and saturation recovery (SR) sequences (Center out Phase-Encoding acquisition) were used. A phantom was designed to hold 25 vials which contained either different (between 0 and 19.77 mmol/L) or constant (1.20 mmol/L) concentrations of contrast agent. The vials of constant concentration were used for the measurement of coil non-uniformity, which was normalized to give a correction factor. The vials of different concentrations were used to measure the SI by using different sequences and different T I and T S values. To calculate the corrected SI for different concentrations, we multiplied the SI of each vial by its correction factor. The relationships between the corrected SI and the concentration [were evaluated], where the threshold of (R 2 = 0.95 and 0.99) was maintained. This study shows that different sequences and different T I and T S values can have an effect on the correlation between the SI and concentration. Regardless of the values of T I, T S, and the different IR and SR sequences chosen, the linear relationship between the SI and concentration was about twice that previously reported (i.e., 0.8 mmol/L, R 2 = 0.95). © 2010 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
dc.language.isoEnglish
dc.relation.ispartofRadiological Physics and Technology
dc.subjectcontrast medium
dc.subjectgadolinium pentetate
dc.subjectarticle
dc.subjectconcentration (parameters)
dc.subjectcontrolled study
dc.subjectimage analysis
dc.subjectimage processing
dc.subjectimage quality
dc.subjectinversion time
dc.subjectnuclear magnetic resonance imaging
dc.subjectphantom
dc.subjectpriority journal
dc.subjectradiological parameters
dc.subjectsaturation time
dc.subjectsignal intensity
dc.subjectsignal noise ratio
dc.subjectT1 weighted magnetic resonance imaging
dc.subjectContrast Media
dc.subjectImage Processing, Computer-Assisted
dc.subjectLinear Models
dc.subjectMagnetic Resonance Imaging
dc.subjectTime Factors
dc.titleEffects of inversion and saturation times on relationships between contrast agent concentrations and signal intensities of T 1-weighted magnetic resonance images
dc.typeArticle
dc.citation.volume3
dc.citation.issue2
dc.citation.spage120
dc.citation.epage126
dc.citation.indexScopus
dc.identifier.DOIhttps://doi.org/10.1007/s12194-010-0087-9


فایلهای درون آیتم

فایلهاسایزفرمتنمایش

هیچ فایل مرتبطی وجود ندارد

این آیتم در مجموعه های زیر مشاهده می شود

نمایش پرونده ساده آیتم