نمایش پرونده ساده آیتم

dc.contributor.authorAzizi, S
dc.contributor.authorKhoubnasabjafari, M
dc.contributor.authorShahrisa, A
dc.contributor.authorKhoubnasabjafari, M
dc.contributor.authorSoleymani, J
dc.contributor.authorJouyban, A
dc.date.accessioned2018-08-26T08:52:57Z
dc.date.available2018-08-26T08:52:57Z
dc.date.issued2017
dc.identifier10.15171/PS.2017.29
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/53845
dc.description.abstractBackground: Malondialdehyde (MDA) is a commonly used biomarker of oxidative stress in clinical studies and has been measured in many pathological conditions during last decades. Different analytical methods have been reported for determination of MDA in biological samples in which MDA was adducted with thiobarbituric acid (TBA) to produce more sensitive chromophore and also convert it to a fluorescent compound. In spite of the routine applications of this derivatization and subsequent analysis of MDA in biomedical studies, its reliability, repeatability and reproducibility is questionable. The aim of this work is to investigate the effects of some factors on the repeatability of MDA determinations in standard solutions and also in plasma samples using spectroscopic method. Methods: MDA-TBA adduct is prepared in standard solutions and the effects of pH, temperature, reaction time, open, closed and reflux systems and the ratio of MDA and TBA is investigated by measuring the absorbance of the solution at 532 nm. These effects are also investigated in human plasma samples. Results: The best results are obtained at pH 2.5, temperature of 70 °C, reaction time of 150 minutes, reflux system and ratio of 2. Conclusion: Using the optimized conditions are resulted in better repeatability. © 2017 The Authors.
dc.language.isoEnglish
dc.relation.ispartofPharmaceutical Sciences
dc.subjectmalonaldehyde
dc.subjectthiobarbituric acid
dc.subjectanalytic method
dc.subjectaqueous solution
dc.subjectArticle
dc.subjecthuman
dc.subjectmass spectrometry
dc.subjectmeasurement repeatability
dc.subjectpH measurement
dc.subjectplasma
dc.subjectprocess optimization
dc.subjectreaction time
dc.subjectreproducibility
dc.titleEffects of analytical procedures on the repeatability of malondialdehyde determinations in biological samples
dc.typeArticle
dc.citation.volume23
dc.citation.issue3
dc.citation.spage193
dc.citation.epage197
dc.citation.indexScopus


فایلهای درون آیتم

Thumbnail

این آیتم در مجموعه های زیر مشاهده می شود

نمایش پرونده ساده آیتم