نمایش پرونده ساده آیتم

dc.contributor.authorHafezeqoran, A
dc.contributor.authorKoodaryan, R
dc.date.accessioned2018-08-26T08:52:53Z
dc.date.available2018-08-26T08:52:53Z
dc.date.issued2017
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/53829
dc.description.abstractBackground. The information available about osseointegration and the bone to implant interaction of zirconia implants with various surface modifications is still far from sufficient. Objective. The purpose of this systematic review and meta-analysis was to evaluate and compare zirconia dental implants with different surface topographies, with a focus on bone to implant contact and removal torque. Methods. The systematic review of the extracted publications was performed to compare the bone to implant contact (BIC) with removal torque (RT) values of titanium dental implants and machined and surfaced modified zirconia implants. Results. A total of fifteen articles on BIC and RT values were included in the quantitative analysis. No significant difference in the BIC values was observed between titanium and machined zirconia implants (p=0.373; 95% CI: -0.166 to 0.443). However, a significantly better BIC values were observed for acid etched zirconia implants compared with those of titanium implants (p=0.032; 95% CI: 0.068 to 1.461). Unmodified zirconia implants showed favorable BIC values compared to modified-surface zirconia implants (p=0.021; 95% CI: -0.973 to -0.080). Conclusion. Acid etched zirconia implants may serve as a possible substitute for successful osseointegration. © 2017 Ali Hafezeqoran and Roodabeh Koodaryan.
dc.language.isoEnglish
dc.relation.ispartofBioMed Research International
dc.subjectsilver
dc.subjecttitanium
dc.subjectzirconium oxide
dc.subjecttooth implant
dc.subjectzirconium
dc.subjectbone regeneration
dc.subjectbone to implant contact
dc.subjectnonhuman
dc.subjectphysical parameters
dc.subjectquantitative analysis
dc.subjectremoval torque
dc.subjectReview
dc.subjectsurface property
dc.subjectsystematic review
dc.subjecttooth implant
dc.subjecttorque
dc.subjectbone
dc.subjectchemistry
dc.subjectdental acid etching
dc.subjecthuman
dc.subjectmeta analysis
dc.subjectpathology
dc.subjectprocedures
dc.subjectprosthesis design
dc.subjectsurface property
dc.subjectAcid Etching, Dental
dc.subjectBone and Bones
dc.subjectDental Implants
dc.subjectDental Prosthesis Design
dc.subjectHumans
dc.subjectOsseointegration
dc.subjectSurface Properties
dc.subjectTitanium
dc.subjectTorque
dc.subjectZirconium
dc.titleEffect of Zirconia Dental Implant Surfaces on Bone Integration: A Systematic Review and Meta-Analysis
dc.typeArticle
dc.citation.volume2017
dc.citation.indexScopus
dc.identifier.DOIhttps://doi.org/10.1155/2017/9246721


فایلهای درون آیتم

فایلهاسایزفرمتنمایش

هیچ فایل مرتبطی وجود ندارد

این آیتم در مجموعه های زیر مشاهده می شود

نمایش پرونده ساده آیتم