Show simple item record

dc.contributor.authorPormohammad, A
dc.contributor.authorRiahi, S-M
dc.contributor.authorNasiri, MJ
dc.contributor.authorFallah, F
dc.contributor.authorAghazadeh, M
dc.contributor.authorDoustdar, F
dc.contributor.authorPouriran, R
dc.date.accessioned2018-08-26T08:51:45Z
dc.date.available2018-08-26T08:51:45Z
dc.date.issued2017
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/53511
dc.description.abstractIntroduction The measurement of adenosine deaminase (ADA) level in cerebrospinal fluid (CSF) has generated as a suitable test for tuberculous meningitis (TBM) diagnosis. The main objective in the present meta-analysis focused on analyzing the ADA test accuracy in order to diagnose TBM. Methods We searched several databases including Medline, Embase and Cochrane databases to identify studies addressing the diagnosis of TBM. The quality of included reports were assessed by RevMan5 software (via QUADS2 checklist). Accuracy measures of ADA test (sensitivity, specificity and others) pooled with random effects models. In addition, the data was elicited by using midas and metan packages in stata (version 12). Result: Twenty studies were eligible for inclusion within the meta-analysis. The pooled sensitivity and specificity for TBM diagnosis hallmarks were 89% (95% CI: 0.84–0.92) and 91% (95% CI: 0.87–0.93), respectively. The positive likelihood ratio was 9.4 (95% CI: 7–12.8), negative likelihood ratio was 0.12 (95% CI: 0.09–0.17), and diagnostic odds ratio was 77 (95% CI: 45–132). Indeed, the area under the summary receiver operating characteristic (SROC) was 0.96. Conclusion It was magnificently attained that ADA test had a relatively high accuracy for TBM diagnosis. آ© 2017
dc.language.isoEnglish
dc.relation.ispartofJournal of Infection
dc.subjectadenosine deaminase
dc.subjectadenosine deaminase
dc.subjectaseptic meningitis
dc.subjectbacterial meningitis
dc.subjectcerebrospinal fluid analysis
dc.subjectcerebrospinal fluid level
dc.subjectdiagnostic test accuracy study
dc.subjectenzyme activity
dc.subjectfalse negative result
dc.subjectfalse positive result
dc.subjecthuman
dc.subjectmeta analysis
dc.subjectneurologic disease
dc.subjectReview
dc.subjectsensitivity and specificity
dc.subjectsystematic review
dc.subjecttuberculous meningitis
dc.subjectcerebrospinal fluid
dc.subjectenzyme assay
dc.subjectenzymology
dc.subjectmicrobiology
dc.subjectodds ratio
dc.subjectreceiver operating characteristic
dc.subjecttuberculous meningitis
dc.subjectAdenosine Deaminase
dc.subjectClinical Enzyme Tests
dc.subjectHumans
dc.subjectOdds Ratio
dc.subjectROC Curve
dc.subjectSensitivity and Specificity
dc.subjectTuberculosis, Meningeal
dc.titleDiagnostic test accuracy of adenosine deaminase for tuberculous meningitis: Aآ systematic review and meta-analysis
dc.typeArticle
dc.citation.volume74
dc.citation.issue6
dc.citation.spage545
dc.citation.epage554
dc.citation.indexScopus
dc.identifier.DOIhttps://doi.org/10.1016/j.jinf.2017.02.012


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record