نمایش پرونده ساده آیتم

dc.contributor.authorMirzaei, M
dc.contributor.authorTaheri, N
dc.contributor.authorMirzaei, H
dc.contributor.authorNajafi, A
dc.contributor.authorMirzaei, S
dc.date.accessioned2018-08-26T08:51:10Z
dc.date.available2018-08-26T08:51:10Z
dc.date.issued2014
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/53276
dc.description.abstractAIM: To evaluate distribution of corneal biomechanical measurements in normal myopia and myopic-astigmatism population. METHODS: One hundred and eighty eyes with myopia and myopic-astigmatism candidated for laser refractive surgery were included in this study. Complete examination of anterior and posterior segments, manifest refraction spherical equivalent (MRSE), Orbscan and Zywave were performed preoperatively. Ocular response analyzer (ORA) was used to measure corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg) and corneal compensated IOP (IOPcc). Distribution of all corneal biomechanical properties and correlation between these parameters and MRSE, age and sex were determined. Statistical analysis was performed using SPSS 17 software and a P-Value less than 0.05 was considered significant. RESULTS: Mean age was 28.20آ±6.78 years. Mean MRSE was -4.21آ±1.19D. Mean CH, CRF, IOPg and IOPcc was 10.00آ±1.28mmHg, 10.17آ±1.45mmHg, 15.71آ±2.67mmHg and 16.68آ±2.41mmHg respectively. 28.4% of all myopic population had CH about 10mmHg, and 71% had CH, 9mmHg up to 11mmHg. CRF in 25.9% of myopic population was 10mmHg, and in 48.7% was 9mmHg up to 11mmHg. There was very poor positive correlation between MRSE& CH (Rs=0.001, P=0.71) and MRSE& CRF (Rs=0.01, P=0.18). CONCLUSION: Our study demonstrated the distribution of corneal biomechanical properties (CH, CRF, IOPg, IOPcc) in normal myopia and myopic-astigmatism population in Iran, and confirmed that, there was no statistically significant correlation between CH, CRF and MRSE, age and sex but there was significant correlation between IOPg, IOPcc and formerly mentioned parameters.
dc.language.isoEnglish
dc.relation.ispartofInternational Eye Science
dc.subjectadult
dc.subjectarticle
dc.subjectastigmatism
dc.subjectbiomechanics
dc.subjectcorneal biomechanic
dc.subjectcorneal compensated intraocular pressure.
dc.subjectcorneal hysteresis
dc.subjectcorneal resistance factor
dc.subjectfemale
dc.subjectgoldmann correlated intraocular pressure
dc.subjecthuman
dc.subjectintraocular pressure
dc.subjectlaser surgery
dc.subjectmajor clinical study
dc.subjectmale
dc.subjectmiddle aged
dc.subjectmyopia
dc.subjectpreoperative evaluation
dc.subjectpreoperative period
dc.subjectrefractive surgery
dc.subjectvisual system parameters
dc.subjectyoung adult
dc.titleCorneal biomechanical properties distribution in myopic population
dc.typeArticle
dc.citation.volume14
dc.citation.issue3
dc.citation.spage390
dc.citation.epage393
dc.citation.indexScopus
dc.identifier.DOIhttps://doi.org/10.3980/j.issn.1672-5123.2014.03.03


فایلهای درون آیتم

Thumbnail

این آیتم در مجموعه های زیر مشاهده می شود

نمایش پرونده ساده آیتم