Show simple item record

dc.contributor.authorEbrahimi, SM
dc.contributor.authorReihani, RD
dc.contributor.authorShiri, Z
dc.contributor.authorMosavi, SMS
dc.contributor.authorMemar, MY
dc.date.accessioned2018-08-26T08:36:59Z
dc.date.available2018-08-26T08:36:59Z
dc.date.issued2015
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/52800
dc.description.abstractBackground and purpose: Awareness of people about drinking water impurities and the demand for better water quality have led to widespread application of point-of-use (POU) water treatment devices. The aim of this study was to investigate the bacteriological quality of water produced by household water treatment devices. Materials and methods: This cross-sectional descriptive study was performed on 18 household water treatment devices in 2014. Thirty-six inlet and outlet water samples were collected. Bacterial quality of the samples were determined by total and fecal coliform multiple-tube fermentation techniques, heterotrophic plate count (HPC) was done using membrane filter technique on blood agar medium and gram-negative bacteria analysis was performed via membrane filtration technique on EMB agar medium. Isolated colonies were identified using standard biochemical tests. Results: Total and fecal coliform bacteria were negative at all inlet samples, but were positive at two of the outlet samples. HPC were higher than the maximum limits of 500 cfu/ml at 67% of the outlet samples. Pseudomonas, Alcaligenes, Serratia and Shigella genus were found with higher frequencies at both inlet and outlet samples. However, frequencies of Proteus and gram positive Bacillus have increased in the outlet samples. Conclusion: The removal of residual chlorine by household water treatment devices causes developing biofilm on the filters and storage tank of the devices by the bacteria present in distribution network. Consequently, the number and variety of bacteria are increased in water produced by POU water treatment devices. é 2015 Mazandaran University of Medical Sciences. All rights reserved.
dc.language.isoPersian
dc.relation.ispartofJournal of Mazandaran University of Medical Sciences
dc.subjectAlcaligenes
dc.subjectArticle
dc.subjectBacillus
dc.subjectcoliform bacterium
dc.subjectcross-sectional study
dc.subjectdevices
dc.subjectfeces analysis
dc.subjecthousehold water treatment device
dc.subjectmembrane filter
dc.subjectProteus
dc.subjectPseudomonas
dc.subjectSerratia
dc.subjectShigella
dc.subjectwater quality
dc.titleBacteriological quality of water produced by household water treatment devices
dc.typeArticle
dc.citation.volume25
dc.citation.issue130
dc.citation.spage8
dc.citation.epage18
dc.citation.indexScopus