Show simple item record

dc.contributor.authorTabrizi, AB
dc.contributor.authorBahrami, F
dc.contributor.authorBadrouj, H
dc.date.accessioned2018-08-26T08:33:10Z
dc.date.available2018-08-26T08:33:10Z
dc.date.issued2017
dc.identifier10.15171/PS.2017.08
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/52394
dc.description.abstractBackground: Methyldopa is a catecholamine widely used as an antihypertensive agent. Pioglitazone is an oral anti-hyperglycemic agent. It is used for the treatment of diabetes mellitus type 2. A survey of the literature reveals that only one spectrofluorimetric method has been reported for the determination of pioglitazone in pharmaceutical preparations. Atenolol and metoprolol are prescription drugs of the ?-blocker class with hypotensive action to treat angina, MI, alcohol syndrome, hypertension, and arrhythmias. A survey of the literature reveals that several spectrofluorimetric methods have been reported for the determination of atenolol and metoprolol in pharmaceutical preparations. In continuing of our studies on the developing of simple and fast spectrofluorimetric methods for determination of drugs and active ingredients, in this work we have developed a spectrofluorimetric method based on the oxidation with cerium (IV) for the determination of studied drugs in their pharmaceutical formulations. Methods: A simple, rapid and sensitive spectrofluorimetric method was developed for the determination of studied drugs in pharmaceutical formulations. Proposed method is based on the oxidation of these drugs with Ce (IV) to produce Ce (III), and its fluorescence was monitored at 356 آ± 3 nm after excitation at 254 آ± 3 nm. Results: The variables affecting oxidation of each drug were studied and optimized. Under the experimental conditions used, the calibration graphs were linear over the range of 25-450, 50-550, 15-800 and 15-800 ng/mL in the case of atenolol, metoprolol, pioglitazone and methyldopa, respectively. The limit of detection was found to be 8.27, 16.5, 1.52 and 5.08 ng/mL in the case of atenolol, metoprolol, pioglitazone and methyldopa, respectively. Intra-and inter-day assay precisions, expressed as the relative standard deviation (RSD), were lower than 3% in all cases. Conclusion: The proposed method was applied to the determination of studied drugs in their pharmaceutical formulations by good recoveries in the range 92-113%. آ© 2017 The Authors.
dc.language.isoEnglish
dc.relation.ispartofPharmaceutical Sciences
dc.subjectatenolol
dc.subjectcerium
dc.subjectmethyldopa
dc.subjectmetoprolol
dc.subjectpioglitazone
dc.subjectsulfuric acid
dc.subjectampoule
dc.subjectArticle
dc.subjectdrug capsule
dc.subjectdrug determination
dc.subjectdrug structure
dc.subjectlimit of detection
dc.subjectmeasurement precision
dc.subjectoxidation
dc.subjectreproducibility
dc.subjectsensitivity analysis
dc.subjectspectrofluorometry
dc.subjecttablet
dc.subjecttemperature
dc.subjecttime
dc.titleA very simple and sensitive spectrofluorimetric method based on the oxidation with cerium (IV) for the determination of four different drugs in their pharmaceutical formulations
dc.typeArticle
dc.citation.volume23
dc.citation.issue1
dc.citation.spage50
dc.citation.epage58
dc.citation.indexScopus
dc.identifier.DOIhttps://doi.org/10.15171/PS.2017.08


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record