Show simple item record

dc.contributor.authorGhiasi, H
dc.contributor.authorMesbahi, A
dc.date.accessioned2018-08-26T08:32:27Z
dc.date.available2018-08-26T08:32:27Z
dc.date.issued2012
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/52293
dc.description.abstractBackground: Photoneutrons are produced in radiation therapy with high energy photons. Also, capture gamma rays are the byproduct of neutrons interactions with wall material of radiotherapy rooms. Aim: In the current study an analytical formula was proposed for capture gamma dose calculations in double bend mazes in radiation therapy rooms. Materials and methods: A total of 40 different layouts with double-bend mazes and a 18. MeV photon beam of Varian 2100 Clinac were simulated using MCNPX Monte Carlo (MC) code. Neutron capture gamma ray dose equivalent was calculated by the MC method along the maze and at the maze entrance door of all the simulated rooms. Then, all MC resulted data were fitted to an empirical formula for capture gamma dose calculations. Wu-McGinley analytical formula for capture gamma dose equivalent at the maze entrance door in single-bend mazes was also used for comparison purposes. Results: For capture gamma dose equivalents at the maze entrance door, the difference of 2-11% was seen between MC and the derived equation, while the difference of 36-87% was found between MC and the Wu-McGinley methods. Conclusion: Our results showed that the derived formula results were consistent with the MC results for all of 40 different geometries. However, as a new formula, further evaluations are required to validate its use in practical situations. Finally, its application is recommend for capture gamma dose calculations in double-bend mazes to improve shielding calculations. é 2012 Greater Poland Cancer Centre.
dc.language.isoEnglish
dc.relation.ispartofReports of Practical Oncology and Radiotherapy
dc.subjectarticle
dc.subjectcontrolled study
dc.subjectdosimetry
dc.subjectempirical research
dc.subjectgamma radiation
dc.subjectgeometry
dc.subjectneutron capture therapy
dc.subjectphoton therapy
dc.subjectvalidation process
dc.titleA new analytical formula for neutron capture gamma dose calculations in double-bend mazes in radiation therapy
dc.typeArticle
dc.citation.volume17
dc.citation.issue4
dc.citation.spage220
dc.citation.epage225
dc.citation.indexScopus
dc.identifier.DOIhttps://doi.org/10.1016/j.rpor.2012.03.011


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record